SUN HYDRAULICS
CKCALDV


$89.65 USD
  • SUN HYDRAULICS
  • Material:CKCALDV
  • Model:CKCA-LDV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKCALDV (CKCALDV) is a versatile pilot-to-open check valve designed for hydraulic systems requiring reliable load holding and hose break protection. This model features a non-sealed pilot and a Delrin seat, suitable for medium pressure systems that may encounter dirty conditions but are not exposed to high flows or temperatures. It operates by allowing free flow from port 2 to the load port 1 while blocking flow in the opposite direction. The valve opens when pressure is applied at the pilot port 3, which needs to be proportional to the load pressure at port 1 for operation. The CKCALDV supports a maximum flow capacity of 15 gpm (60 L/min) and can handle up to 2500 psi (175 bar) of operating pressure. Its design includes an optional external porting configuration for external piloting, enhancing its adaptability for different system requirements. Notably, this valve is not intended as a motion control valve; instead, it should be used in applications where locking under pressurized conditions is necessary. In terms of construction, the CKCALDV incorporates Sun's floating style design which minimizes internal parts binding due to installation torque variations or cavity/cartridge machining discrepancies. This feature ensures reliable operation and longevity of the valve even under challenging installation conditions. The model also offers extremely low leakage characteristics; however, if any drift occurs due to valve issues, it typically indicates seat damage from contamination, suggesting replacement might be necessary. Overall, the Sun Hydraulics CKCALDV provides robust performance for systems requiring dependable non-vented load holding capabilities with minimal maintenance needs and operational reliability in environments with medium pressure and potential contamination.

This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve, allowing flow from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 15 gpm60 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight .20 lb0,10 kg
Seal kit - Cartridge Viton: 990-011-006