***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKCBDEV (CKCBDEV) is a pilot-to-open check valve designed for efficient hydraulic flow management. It features a non-sealed pilot, a steel seat, and is non-vented, ensuring robust operation under various conditions. This valve facilitates free flow from port 2 to load port 1 and blocks flow in the reverse direction. The operation of the valve is influenced by pressure at pilot port 3, which opens the valve to allow flow from port 1 to port 2. The required pilot pressure at port 3 is directly proportional to the load pressure at port 1, with opposing pressure at port 2. This model is interchangeable with 3-port counterbalance valves in terms of physical dimensions and flow paths for specific frame sizes, although cartridge extension dimensions may vary. It offers critical functionalities such as hose break protection, prevention of load drifting, and positive locking of pressurized loads. Its standard unsealed pilot aids in air purging within the pilot line, contributing to circuit efficiency. The CKCBDEV boasts extremely low leakage rates and includes options for external piloting. Its construction integrates Sun’s floating style design which minimizes internal part binding due to installation torque or cavity/cartridge machining variations. The valve's durability is enhanced by heat-treated components such as the seat and poppet. Notably designed for applications requiring reliable load holding rather than motion control (for which counterbalance valves are recommended), it operates optimally up to a maximum pressure of 5000 psi (350 bar) and can handle flows up to 15 gpm (60 L/min). Optional configurations with EPDM seals cater to systems using phosphate ester fluids while avoiding damage from petroleum-based substances. For corrosive environments, variants with stainless steel or zinc-nickel plated external components are available. This model's adaptability makes it suitable for diverse hydraulic applications demanding precise backflow prevention and operational reliability.

This valve is a pilot to open check valve. It has a non-sealed pilot, a steel seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
  • Extremely low leakage. The seat and poppet are heat treated for long life. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 15 gpm60 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight .20 lb0,10 kg
Seal kit - Cartridge Viton: 990-011-006