You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CKCISFN


$60.36 USD
  • SUN HYDRAULICS
  • Material:CKCISFN
  • Model:CKCI-SFN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKCISFN (CKCISFN) is a high-performance pilot-to-open check valve designed for hydraulic applications requiring reliable load holding and hose break protection. This model features a sealed pilot and steel seat, ensuring minimal leakage and robust performance under challenging conditions. The valve facilitates free flow from port 2 to load port 1 and blocks flow in the opposite direction, with the ability to control the flow based on external pilot pressure at port 3. The CKCISFN valve is characterized by its vented design, which makes it insensitive to pressure changes at port 2 due to the spring chamber referencing the vent port 3. It offers a maximum operating pressure of 5000 psi (350 bar) and can handle up to 15 gpm (60 L/min), making it suitable for a wide range of hydraulic applications. The valve's pilot ratio of 3:1 ensures that pilot pressure required to open the valve is proportional to the load pressure at port 1, providing precise control over hydraulic loads. Notably, this model incorporates Sun’s floating style construction which minimizes potential internal parts binding caused by excessive installation torque or cavity/cartridge machining variations. This design feature enhances the reliability and longevity of the valve in various installations. Furthermore, its compact size (.20 lb/0.10 kg) and specific cavity requirements (T11A) make it an ideal choice for systems where space and compatibility are critical. The CKCISFN is directly replaceable with older models such as CKE, CKF, CKEG, and CKH but does not share their proportional pressure-reducing characteristics, potentially increasing actuator pressure by up to 33% when replacing older designs. This makes it essential for users to consider system adjustments when upgrading from previous models to ensure optimal performance.

This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the external pilot port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber references the vent (port 3).

  • There is a positve seal between ports 2 and 3.
  • These valves should be considered service items only. New applications should use valves from the CV*V family.
  • Pilot pressure as low as 75 psi (5 bar) higher than the pressure at the vent can prevent the valve from closing.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • This 3 port pilot-to-open check valve is not physically interchangeable with other 3 port pilot-to-open check valves or counterbalance valves due to the different pilot/vent configuration.
  • This valve is a direct replacement for the CK*E, CK*F, CKEG, and CK*H and uses components from the new vented design. It does not have the proportional pressure reducing characteristic. Note: Replacing the older design with this valve can result in a 33% increase in pressure at the actuator.
  • Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 15 gpm60 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight .20 lb0,10 kg
Seal kit - Cartridge Viton: 990-011-006