SUN HYDRAULICS
CKCIVFV


$68.30 USD
  • SUN HYDRAULICS
  • Material:CKCIVFV
  • Model:CKCI-VFV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKCIVFV (CKCIVFV) is a high-performance pilot-to-open check valve designed for hydraulic applications requiring reliable load holding and prevention of flow reversal. This valve allows free flow from port 2 to load port 1 and blocks flow in the opposite direction, ensuring operational stability and safety. The external pilot pressure opens the valve from port 1 to port 2, with the required pilot pressure being directly proportional to the load pressure at port 1. This feature makes the CKCIVFV particularly effective in systems where load pressures vary. Constructed with a steel seat and sealed pilot, the CKCIVFV boasts extremely low leakage rates, enhancing system efficiency and reducing maintenance needs. It is vented, referencing the spring chamber to vent port 3, which makes it insensitive to pressure at port 2. This insensitivity helps maintain consistent operation regardless of fluctuations in return line pressures. The CKCIVFV features a positive seal between ports 2 and 3 and incorporates Sun's floating style construction to minimize potential internal parts binding caused by installation torque or machining variations. With a capacity of up to 15 gpm (60 L/min) and a maximum operating pressure of 5000 psi (350 bar), this valve is robust enough for demanding applications. It also provides hose break protection, preventing loads from drifting and positively locking pressurized loads. This model is specifically designed as a direct replacement for older models such as CKE, CKF, CKEG, and CKH but does not possess proportional pressure-reducing characteristics. When replacing older designs with this model, users may experience an increase in actuator pressure by approximately 33%. The valve's installation requires specific torque (30 – 35 lbf ft or approximately 41 – 47 Nm) and it features a hex size for easy integration into existing systems. Overall, the Sun Hydraulics CKCIVFV check valve is an essential component for hydraulic systems requiring efficient load holding capabilities coupled with high reliability under varying operational pressures.

This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the external pilot port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber references the vent (port 3).

  • There is a positve seal between ports 2 and 3.
  • These valves should be considered service items only. New applications should use valves from the CV*V family.
  • Pilot pressure as low as 75 psi (5 bar) higher than the pressure at the vent can prevent the valve from closing.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • This 3 port pilot-to-open check valve is not physically interchangeable with other 3 port pilot-to-open check valves or counterbalance valves due to the different pilot/vent configuration.
  • This valve is a direct replacement for the CK*E, CK*F, CKEG, and CK*H and uses components from the new vented design. It does not have the proportional pressure reducing characteristic. Note: Replacing the older design with this valve can result in a 33% increase in pressure at the actuator.
  • Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 15 gpm60 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight .20 lb0,10 kg
Seal kit - Cartridge Viton: 990-011-006