SUN HYDRAULICS
CKEBLZN


$72.57 USD
  • SUN HYDRAULICS
  • Material:CKEBLZN
  • Model:CKEB-LZN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKEBLZN (CKEBLZN) is a pilot-to-open check valve designed for hydraulic systems, characterized by its ability to allow free flow from port 2 to load port 1 while blocking flow in the opposite direction. This valve operates with a non-sealed pilot and a steel seat, and it is non-vented, which helps in purging air trapped in the pilot line from the circuit. The pressure required at pilot port 3 to open the valve is directly proportional to the load pressure at port 1, with backpressure at port 2 opposing this pilot pressure. This model features an optional manual load release control, which can be activated by turning clockwise to release the load. It is suitable for use with phosphate ester fluids when configured with EPDM seals but should not be exposed to petroleum-based fluids as they can damage the seals. The valve provides hose break protection and prevents drifting of loads while locking pressurized loads securely. The CKEBLZN incorporates Sun's floating style construction that minimizes internal parts binding due to excessive installation torque or cavity/cartridge machining variations. With extremely low leakage rates and heat-treated seat and poppet for durability, this valve ensures reliable operation even under high pressures up to 5000 psi (350 bar). Optional external porting out of the hex end of the cartridge allows for external piloting configurations where port 3 is blocked. Designed primarily as a locking valve rather than a motion control valve, it should be used in conjunction with counterbalance valves for motion control applications. The cartridge also comes with corrosion-resistant options suitable for corrosive environments, marked by model code suffixes AP for external stainless steel components or LH for external zinc-nickel plated components.

This valve is a pilot to open check valve. It has a non-sealed pilot, a steel seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
  • Extremely low leakage. The seat and poppet are heat treated for long life. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 30 gpm120 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Model Weight .50 lb0,25 kg
Seal kit - Cartridge Viton: 990-202-006

Show FAQ