***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKECEFN (CKECEFN) is a pilot-to-open check valve designed for hydraulic systems requiring reliable load holding and hose break protection. This valve permits free flow from port 2 to the load port 1 while blocking flow in the reverse direction. It features a sealed pilot to prevent cross-port leakage and an optional external porting configuration for external piloting, with port 3 being blocked in this setup. The Delrin seat within the valve makes it suitable for medium pressure systems that are not subjected to high flows or temperatures, offering an advantage in environments where contamination is a concern due to its extremely low leakage characteristics. The CKECEFN incorporates Sun Hydraulics' floating style construction which minimizes internal parts binding, ensuring consistent operation even when installation torque varies or there are cavity/cartridge machining variations. It has a capacity of 30 gpm (120 L/min), a pilot ratio of 3:1, and can operate at pressures up to 2500 psi (175 bar). The maximum valve leakage is remarkably low at about one drop per minute (0.07 cc/min). The valve's hex size is 1 1/8 inches (28.6 mm) and requires an installation torque between 45-50 lbf ft (61-68 Nm). The model weighs approximately 0.50 lb (0.25 kg). This valve is ideal for applications where hose break protection is crucial and loads need to be positively locked under pressure without risk of drifting. It also supports configurations with manual load release controls for added operational flexibility.

This valve is a pilot to open check valve. It has a sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 30 gpm120 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Model Weight .50 lb0,25 kg
Seal kit - Cartridge Viton: 990-202-006