You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CKECLDN


$135.42 USD
  • SUN HYDRAULICS
  • Material:CKECLDN
  • Model:CKEC-LDN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKECLDN (CKECLDN) is a pilot-to-open check valve designed for hydraulic systems requiring reliable load-holding and hose break protection. This valve allows free flow from port 2 to port 1 while blocking flow in the opposite direction, making it ideal for applications where reverse flow must be prevented to maintain system integrity and safety. The valve features a sealed pilot to prevent cross-port leakage, enhancing its performance in circuits where such leakage is undesirable. The CKECLDN operates with a pilot pressure at port 3 that is directly proportional to the load pressure at port 1, with pressure at port 2 opposing the pilot pressure. This configuration ensures that the valve only opens under controlled conditions, preventing accidental release of pressurized loads. The Delrin seat within the valve makes it suitable for use in environments with medium pressures and where system cleanliness is not guaranteed, as it can handle some degree of contamination without significant leakage. This model also incorporates Sun's floating style construction which minimizes potential internal binding caused by excessive installation torque or variations in cavity/cartridge machining. Optional external porting from the hex end of the cartridge offers flexibility for external piloting configurations, further enhancing its adaptability to different hydraulic systems. With a maximum operating pressure of 2500 psi (175 bar) and a capacity of up to 30 gpm (120 L/min), this valve is robust enough for various industrial applications. Its design ensures extremely low leakage; however, if any drift occurs due to the valve, it indicates possible seat damage from contamination, suggesting replacement might be necessary. Additionally, this model provides manual load release control options and can accommodate Viton seals (990202006), ensuring compatibility with various fluids and environmental conditions. This makes the CKECLDN an efficient solution for systems requiring precise control over fluid handling and load management without compromising on reliability or performance.

This valve is a pilot to open check valve. It has a sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 30 gpm120 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Model Weight .50 lb0,25 kg
Seal kit - Cartridge Viton: 990-202-006

Show FAQ