You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CKGAXEV


$256.54 USD
  • SUN HYDRAULICS
  • Material:CKGAXEV
  • Model:CKGA-XEV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKGAXEV (CKGAXEV) is a pilot-to-open check valve designed for hydraulic systems, featuring a non-sealed pilot, a Delrin seat, and non-vented configuration. This valve allows free flow from port 2 to the load port 1 and blocks flow in the opposite direction. The opening of the valve is controlled by pressure at pilot port 3, which needs to be proportional to the load pressure at port 1 for activation. The presence of pressure at port 2 directly opposes this pilot pressure. This model offers several key functionalities, including hose break protection and prevention of load drift, which are essential for maintaining system stability and safety. It also features an optional external piloting via an external port on the hex end of the cartridge, which can be beneficial in specific configurations where internal pilot pressures need management. The CKGAXEV is particularly noted for its low leakage rates and robust design that minimizes internal parts binding, a common issue due to installation torque or cavity/cartridge machining variations. It operates with a maximum capacity of 60 gpm (240 L/min) and can handle up to 2500 psi (175 bar). The valve's standard unsealed pilot design helps purge air trapped in the pilot line, enhancing system efficiency. This model is ideal for applications requiring reliable check functionalities in medium-pressure systems that are not subjected to high flows or temperatures. Its design ensures durability and performance even in environments with potential contamination, thanks to its Delrin seat which provides resilience against particulate matter while maintaining seal integrity under moderate conditions.

This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve, allowing flow from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-17A
Series 3
Capacity 60 gpm240 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Model Weight 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-017-006

Show FAQ