***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKGCXDV (CKGCXDV) is a pilot-to-open check valve designed for hydraulic systems requiring reliable load holding and hose break protection. This valve facilitates free flow from port 2 to load port 1 while blocking flow in the opposite direction. The operation of the CKGCXDV is contingent on pressure at pilot port 3, which opens the valve allowing flow from port 1 to port 2. The pressure required at port 3 to open the valve is directly proportional to the load pressure at port 1, with backpressure at port 2 opposing this pilot pressure. Featuring a Delrin seat, the CKGCXDV is optimal for medium-pressure systems that are not exposed to high flows or temperatures but may contain some degree of contamination. This valve offers extremely low leakage characteristics; however, if leakage occurs due to load drift, it typically indicates seat damage by contamination, necessitating valve replacement. The sealed pilot design makes this model suitable for applications where cross-port leakage is undesirable. The CKGCXDV also incorporates Sun's floating style construction which minimizes internal parts binding that could result from excessive installation torque or variations in cavity/cartridge machining. Optional external piloting configurations are available by utilizing control options E and P, where port 3 can be blocked if needed. Specifications for this model include a T17A cavity, series 3 designation, up to 60 gpm/240 L/min capacity, a pilot ratio of 3:1/3:1, maximum operating pressure of 2500 psi/175 bar, and maximum valve leakage specified at less than one drop per minute. The valve's hex size is set at 1-1/4 inches (31.8 mm), with an installation torque between 150 -160 lbf ft (203 -217 Nm), and it weighs approximately 1.10 lbs (0.50 kg). For maintenance or repair, Viton seal kits are available under part number:990017006.

This valve is a pilot to open check valve. It has a sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-17A
Series 3
Capacity 60 gpm240 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Model Weight 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-017-006

Show FAQ