  • SUN HYDRAULICS
  • Material:CKGEVCV
  • Model:CKGE-VCV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKGEVCV (CKGEVCV) is a pilot-to-open check valve designed for hydraulic systems requiring reliable load holding and prevention of flow reversal. This valve facilitates free flow from port 2 to port 1 while blocking the opposite direction. Utilizing a sealed pilot and Delrin seat, the CKGEVCV offers enhanced performance in environments where cross-port leakage is undesirable. The valve operates with a proportional pressure-reducing characteristic, maintaining port 1 pressure at approximately 75% of port 2 pressure. Key features of the CKGEVCV include extremely low leakage rates and a vented design that references the spring chamber to the vent port (port 3), making it insensitive to pressure changes at port 2. The required pilot pressure to open the valve is directly proportional to the load pressure on port 1, with additional sensitivity to external pressures as low as 15 psi above vent pressure potentially preventing closure. Designed for medium-pressure systems that may contain contamination, this valve's Delrin seat is particularly suited for dirty conditions, though it is not ideal for high-flow or high-temperature applications. In terms of maintenance, if there is load drift due to valve performance, it indicates potential seat damage by contamination, necessitating replacement. The CKGEVCV incorporates Sun\u2019s floating style construction which minimizes internal parts binding caused by excessive installation torque or variations in cavity/cartridge machining. This specific model has a capacity of up to 60 gpm (240 L/min), can handle maximum operating pressures up to 2500 psi (175 bar), and features a pilot ratio of 3:1. It measures with a hex size of 1-1/4 inches (31.8 mm) and requires an installation torque between 150 -160 lbf ft (203 -217 Nm). Weighing at about 1.10 lb (0.50 kg), this model ensures robust performance in specified applications while offering hose break protection and secure locking under pressurized conditions.

This valve is a pilot to open check valve. It has a sealed pilot, a Delrin seat, and is vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the external pilot port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber references the vent (port 3).

  • There is a positve seal between ports 2 and 3.
  • These valves should be considered service items only. New applications should use valves from the CV*V family.
  • This valve has a proportional pressure reducing characteristic that limits the pressure developed at port 1 to about 75% of the pressure at port 2.
  • Pilot pressure as low as 15 psi (1 bar) higher than the pressure at the vent can prevent the valve from closing.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • This 3 port pilot-to-open check valve is not physically interchangeable with other 3 port pilot-to-open check valves or counterbalance valves due to the different pilot/vent configuration.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-17A
Series 3
Capacity 60 gpm240 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Model Weight 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-017-006