SUN HYDRAULICS
CKGGSCV


$294.37 USD
  • SUN HYDRAULICS
  • Material:CKGGSCV
  • Model:CKGG-SCV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKGGSCV (CKGGSCV) is a pilot-to-open check valve designed to allow free flow from valve port 2 to load port 1 while blocking flow in the opposite direction. This product features a non-sealed pilot, a Delrin seat, and is vented, which ensures pressure at the external pilot port can open the valve from port 1 to port 2. The pilot pressure required to open the valve is directly proportional to the load pressure at port 1, making it insensitive to pressure at port 2 due to its spring chamber referencing the vent port 3. With a positive seal between ports 2 and 3, this valve is particularly useful for applications requiring hose break protection, prevention of load drift, and positive locking of pressurized loads. The CKGGSCV operates with a maximum flow capacity of 60 gpm (240 L/min) and can handle up to a maximum operating pressure of 2500 psi (175 bar). It features an extremely low leakage rate which indicates that if there is any load drift, it could likely be due to seat damage from contamination, necessitating valve replacement. The standard unsealed pilot design allows for purging of air trapped in the pilot line, enhancing operational reliability. This model uses Sun\u2019s floating style construction which minimizes internal parts binding caused by excessive installation torque or cavity/cartridge machining variations. This check valve comes with Viton seals and has specific installation requirements including a torque range of 150-160 lbf ft (203-217 Nm). It weighs approximately 1.10 lb (0.50 kg) and fits into a T17A cavity with a hex size of 1\u00bc inches (31.8 mm). Notably, this model should be considered for service replacements only as new applications are recommended to use valves from Sun Hydraulics' CVV family due to their updated configurations and capabilities.

This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the external pilot port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber references the vent (port 3).

  • There is a positve seal between ports 2 and 3.
  • These valves should be considered service items only. New applications should use valves from the CV*V family.
  • This valve has a proportional pressure reducing characteristic that limits the pressure developed at port 1 to about 75% of the pressure at port 2.
  • Pilot pressure as low as 15 psi (1 bar) higher than the pressure at the vent can prevent the valve from closing.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • This 3 port pilot-to-open check valve is not physically interchangeable with other 3 port pilot-to-open check valves or counterbalance valves due to the different pilot/vent configuration.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-17A
Series 3
Capacity 60 gpm240 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Model Weight 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-017-006