SUN HYDRAULICS
CKGVXBV


$214.55 USD
  • SUN HYDRAULICS
  • Material:CKGVXBV
  • Model:CKGV-XBV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKGVXBV (CKGVXBV) is a high-performance pilot-to-open check valve designed for hydraulic applications requiring reliable load holding and prevention of flow reversal. This valve facilitates free flow from port 2 to load port 1 while blocking the opposite direction, ensuring efficient operation in various hydraulic systems. The presence of a sealed pilot and steel seat enhances its functionality by minimizing cross-port leakage, crucial for applications where such leakage is undesirable. With a pilot ratio of 3:1, the CKGVXBV requires a minimum pilot pressure that is proportional to the load pressure at port 1 to initiate opening, ensuring precise control over the valve operation based on system demands. The valve's design includes a vented spring chamber referenced out the back of the hex body, making it insensitive to pressure changes at port 2. This feature contributes to its stable performance across different operating conditions. The CKGVXBV has a maximum operating pressure capacity of 5000 psi (350 bar) and can handle up to 60 gpm (240 L/min), making it suitable for high-pressure systems. Its robust construction includes heat-treated components for enhanced durability and low maintenance requirements. The valve's installation involves specific torque settings ranging between 150-160 lbf ft (203-217 Nm), ensuring secure placement and operational reliability. This model also offers manual load release control options for user convenience in managing load pressures manually when required. Designed with Sun\u2019s floating style construction, the CKGVXBV minimizes internal parts binding, which could occur due to excessive installation torque or variations in cavity/cartridge machining, thereby promoting longevity and consistent performance in demanding hydraulic environments.

This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) pilot port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced out the back of the hex body.

  • There is a positve seal between ports 2 and 3.
  • Pilot pressure as low as 75 psi (5 bar) higher than the pressure at the vent can prevent the valve from closing.
  • Atmospherically referenced pilot-to-open check valves are considered problem solvers for existing circuits using non-vented valves. However, the atmospherically referenced valve will eventually leak externally or allow moisture into the spring chamber. Four-port vented pilot-to-open check cartridges are recommended for new applications.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Extremely low leakage. The seat and poppet are heat treated for long life. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-17A
Series 3
Capacity 60 gpm240 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Model Weight 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-017-006