You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CKIAPCV


$492.83 USD
  • SUN HYDRAULICS
  • Material:CKIAPCV
  • Model:CKIA-PCV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKIAPCV (CKIAPCV) is a pilot-to-open check valve designed for hydraulic applications requiring load holding and hose break protection. This valve facilitates free flow from port 2 to port 1 while blocking flow in the opposite direction. Activation occurs through pressure at pilot port 3, which must be proportional to the load pressure at port 1 for the valve to open, allowing flow from port 1 to port 2. The model features a non-sealed pilot with a Delrin seat, suitable for medium pressure systems prone to contamination but not high flows or temperatures. The CKIAPCV exhibits extremely low leakage characteristics, making it ideal for applications where minimal fluid loss is critical. If leakage occurs due to load drift, it typically indicates seat damage from contamination, necessitating valve replacement. The valve's design incorporates Sun\u2019s floating style construction which minimizes internal parts binding that can result from excessive installation torque or variations in cavity/cartridge machining. This model also offers optional external piloting from the hex end of the cartridge by blocking port 3, with control options E and P available for such configurations. It's important to note that while this valve locks pressurized loads effectively, it is not intended for motion control applications; counterbalance valves are recommended for such needs. Key specifications include a maximum operating pressure of 2500 psi (175 bar), a capacity of up to 120 gpm (480 L/min), and a pilot ratio of 3:1. The CKIAPCV fits into cavity T19A and requires installation torque between 350 \u2013 375 lbf\u00b7ft (474 \u2013 508 Nm). Its compact design weighs approximately 2.80 lbs (1.30 kg), ensuring it can be integrated into various hydraulic systems without significant spatial or weight concerns.

This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve, allowing flow from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-19A
Series 4
Capacity 120 gpm480 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 5/8 in.41,3 mm
Valve Installation Torque 350 - 375 lbf ft474 - 508 Nm
Model Weight 2.80 lb1,30 kg
Seal kit - Cartridge Viton: 990-019-006

Show FAQ