SUN HYDRAULICS
CKIAPZV


$496.80 USD
  • SUN HYDRAULICS
  • Material:CKIAPZV
  • Model:CKIA-PZV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKIAPZV (CKIAPZV) is a pilot-to-open check valve designed for hydraulic systems. This valve features a non-sealed pilot, a Delrin seat, and is non-vented, providing specific functionality in controlling flow direction under varying pressures. It facilitates free flow from valve port 2 to load port 1 and restricts flow in the opposite direction. The operation of the CKIAPZV is influenced by pressure at pilot port 3 which, when sufficient, opens the valve to allow flow from port 1 to port 2. The required pilot pressure at port 3 is proportional to the load pressure at port 1, with opposing pressure at port 2. This model incorporates Sun Hydraulics' floating style construction which helps minimize potential internal binding caused by excessive installation torque or variations in cavity/cartridge machining. It provides essential hose break protection and prevents load drifting by positively locking pressurized loads. The standard unsealed pilot design allows for the purging of air trapped in the pilot line, enhancing system reliability. The CKIAPZV offers optional external porting for external piloting configurations where port 3 is blocked. Notably designed for medium-pressure systems that may contain some degree of contamination but are not subject to high flows or temperatures, this valve boasts extremely low leakage characteristics. If leakage occurs due to load drift, it typically indicates seat damage from contamination, suggesting replacement of the valve. This model supports up to 120 gpm/480 L/min capacity and can withstand a maximum operating pressure of 2500 psi/175 bar. It has a specified maximum valve leakage rate at very low levels (1 drop/min or 0.07 cc/min), ensuring efficient performance even under stringent conditions. The dimensions and installation requirements include a hex size of 1-5/8 inches (41.3 mm) and an installation torque range between 350 -375 lbf-ft (474 -508 Nm), with an overall weight of approximately 2.80 lb (1.30 kg).

This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve, allowing flow from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-19A
Series 4
Capacity 120 gpm480 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 5/8 in.41,3 mm
Valve Installation Torque 350 - 375 lbf ft474 - 508 Nm
Model Weight 2.80 lb1,30 kg
Seal kit - Cartridge Viton: 990-019-006

Show FAQ