SUN HYDRAULICS
CKIAXCV


$487.86 USD
  • SUN HYDRAULICS
  • Material:CKIAXCV
  • Model:CKIA-XCV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKIAXCV (CKIAXCV) is a pilot-to-open check valve designed for hydraulic systems, featuring a non-sealed pilot and a Delrin seat. This valve facilitates free flow from port 2 to load port 1 while blocking the opposite direction. It operates by allowing pressure at pilot port 3 to open the valve, permitting flow from port 1 to port 2. The required pilot pressure at port 3 is directly proportional to the load pressure at port 1, with backpressure at port 2 opposing this pilot pressure. This model is built with Sun's floating style construction, which helps minimize internal parts binding caused by excessive installation torque or variations in cavity/cartridge machining. The standard unsealed pilot design allows for air purging in the pilot line, enhancing system reliability and performance. An optional external piloting configuration can also be obtained by using control options E and P, where port 3 gets blocked. The CKIAXCV valve is primarily used for hose break protection, preventing load drifting and securely locking pressurized loads. It is not intended for motion control applications; instead, counterbalance valves are recommended for such needs. The Delrin seat makes it suitable for systems that are not exposed to high flows or temperatures but require very low leakage rates. If there's load drift due to valve issues, it typically indicates seat damage from contamination, necessitating valve replacement. Key specifications include a maximum operating pressure of 2500 psi (175 bar), a flow capacity of up to 120 gpm (480 L/min), and an extremely low maximum valve leakage rate at specific conditions. This model also supports manual load release controls and features various customization options to fit specific application requirements.

This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve, allowing flow from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-19A
Series 4
Capacity 120 gpm480 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 5/8 in.41,3 mm
Valve Installation Torque 350 - 375 lbf ft474 - 508 Nm
Model Weight 2.80 lb1,30 kg