***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKIAXDV (CKIAXDV) is a pilot-to-open check valve designed for hydraulic systems requiring reliable load-holding and hose break protection. This model features a non-sealed pilot and a Delrin seat, suitable for medium pressure systems that are not exposed to high flows or temperatures. The valve enables free flow from port 2 to port 1 while blocking flow in the reverse direction. Pilot pressure at port 3 opens the valve, allowing flow from port 1 to port 2, with the required pilot pressure being directly proportional to the load pressure at port 1. This valve is distinguished by its capacity to lock pressurized loads positively, preventing drifting and providing hose break protection. It incorporates Sun\u2019s floating style construction which minimizes internal parts binding due to excessive installation torque or cavity/cartridge machining variations. The standard unsealed pilot facilitates air purging in the pilot line, enhancing operational reliability. The CKIAXDV offers an optional external piloting configuration and supports a maximum operating pressure of 2500 psi (175 bar), with a maximum flow capacity of 120 gpm (480 L/min). Its design allows for extremely low leakage; however, if leakage occurs due to load drift, it usually indicates seat damage by contamination, necessitating valve replacement. For applications not suited to motion control where counterbalance valves are typically used instead, this model serves primarily as a locking mechanism rather than for controlling motion. The manual load release option provides additional utility for controlled release of pressurized loads. Overall, the CKIAXDV is engineered for robust performance in various hydraulic applications where medium pressures and contamination risks are present.

This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve, allowing flow from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-19A
Series 4
Capacity 120 gpm480 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 5/8 in.41,3 mm
Valve Installation Torque 350 - 375 lbf ft474 - 508 Nm
Model Weight 2.80 lb1,30 kg
Seal kit - Cartridge Viton: 990-019-006