SUN HYDRAULICS
CKIFSFN


$344.80 USD
  • SUN HYDRAULICS
  • Material:CKIFSFN
  • Model:CKIF-SFN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKIFSFN (CKIFSFN) is a robust pilot-to-open check valve designed for hydraulic applications requiring reliable load holding and hose break protection. This valve facilitates free flow from port 2 to the load port 1 while blocking flow in the opposite direction. The operation of the valve is contingent on the pressure at an external pilot port, which opens the valve from port 1 to port 2, with the required pilot pressure being directly proportional to the load pressure at port 1. Notably, this model is insensitive to pressure at port 2 due to its spring chamber referencing vent port 3. The CKIFSFN features a steel seat and sealed pilot design, minimizing cross-port leakage and making it suitable for circuits where such leakages are undesirable. It has a positive seal between ports 2 and 3 and provides extremely low leakage characteristics, enhancing system efficiency and safety by preventing load drifting and locking pressurized loads securely. This valve incorporates Sun\u2019s floating style construction which minimizes internal parts binding that could result from excessive installation torque or variations in cavity/cartridge machining. It supports a maximum operating pressure of 5000 psi (350 bar) and has a flow capacity of up to 120 gpm (480 L/min). The model's specific design ensures it is not interchangeable with other three-port pilot-to-open check valves or counterbalance valves due to differing pilot-vent configurations. Designed primarily as a service item for existing systems rather than new applications (which should use valves from Sun's CVV family), this model also features a proportional pressure-reducing characteristic that limits the developed pressure at port 1 to approximately 75% of that at port 2. Additionally, it requires minimal pilot pressure\u2014a low as 15 psi (1 bar) above vent pressure\u2014to prevent closure, ensuring operational reliability even under varied system pressures.

This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the external pilot port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber references the vent (port 3).

  • There is a positve seal between ports 2 and 3.
  • These valves should be considered service items only. New applications should use valves from the CV*V family.
  • This valve has a proportional pressure reducing characteristic that limits the pressure developed at port 1 to about 75% of the pressure at port 2.
  • Pilot pressure as low as 15 psi (1 bar) higher than the pressure at the vent can prevent the valve from closing.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • This 3 port pilot-to-open check valve is not physically interchangeable with other 3 port pilot-to-open check valves or counterbalance valves due to the different pilot/vent configuration.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-19A
Series 4
Capacity 120 gpm480 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 5/8 in.41,3 mm
Valve Installation Torque 350 - 375 lbf ft474 - 508 Nm
Model Weight 2.80 lb1,30 kg
Seal kit - Cartridge Viton: 990-019-006