SUN HYDRAULICS
CKIVXCV


$382.43 USD
  • SUN HYDRAULICS
  • Material:CKIVXCV
  • Model:CKIV-XCV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKIVXCV (CKIVXCV) is a pilot-to-open check valve designed to regulate hydraulic flow with precision and reliability. This valve facilitates free flow from port 2 to the load port 1 and restricts flow in the reverse direction. It operates with a sealed pilot, which prevents cross-port leakage, making it ideal for applications where such leakage could be problematic. The valve features a steel seat for durability and incorporates Sun's floating style construction, which minimizes internal part binding due to installation torque or cavity/cartridge machining variations. Noteworthy is the vented design of this model, which references the spring chamber out the back of the hex body, rendering it insensitive to pressure at port 2. This design aspect is crucial for applications requiring precise control over backpressure impacts. The CKIVXCV has a pilot pressure requirement proportional to the load pressure at port 1, with a minimum pilot pressure of 75 psi needed to prevent the valve from closing when there is higher pressure at the vent. The valve's specifications include a maximum operating pressure of 5000 psi and a capacity of up to 120 gpm. It has a tight leakage specification of approximately one drop per minute, ensuring efficient operation with minimal fluid loss. The manual load release option adds versatility by allowing manual intervention in load control. Designed primarily for use in hydraulic systems requiring robust load holding capabilities, such as mobile hydraulics and industrial applications, this valve provides hose break protection and prevents drifting loads while positively locking pressurized loads. Its application is best suited for circuits where motion control valves are inappropriate due to its operational characteristics as a locking valve rather than a motion control device.

This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) pilot port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced out the back of the hex body.

  • There is a positve seal between ports 2 and 3.
  • Pilot pressure as low as 75 psi (5 bar) higher than the pressure at the vent can prevent the valve from closing.
  • Atmospherically referenced pilot-to-open check valves are considered problem solvers for existing circuits using non-vented valves. However, the atmospherically referenced valve will eventually leak externally or allow moisture into the spring chamber. Four-port vented pilot-to-open check cartridges are recommended for new applications.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Extremely low leakage. The seat and poppet are heat treated for long life. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-19A
Series 4
Capacity 120 gpm480 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 5/8 in.41,3 mm
Valve Installation Torque 350 - 375 lbf ft474 - 508 Nm
Model Weight 2.80 lb1,30 kg
Seal kit - Cartridge Viton: 990-019-006

Show FAQ