SUN HYDRAULICS
CXEDLCV
$52.32 USD
- SUN HYDRAULICS
- Material:CXEDLCV
- Model:CXED-LCV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CXEDLCV (CXEDLCV) is a high-performance hydraulic check valve designed for robust and efficient operation in various hydraulic systems. This valve features a freeflow, side-to-nose configuration, allowing free flow from inlet port 2 to outlet port 1 while blocking flow in the opposite direction. It is specifically engineered to address issues in existing circuits with incorrect manifold drillings, serving as a circuit saver by offering an alternative flow path. The CXEDLCV operates under a maximum pressure of 5000 psi (350 bar) at both ports and supports a flow capacity of up to 30 gpm (120 L/min). Notably, this model ensures minimal leakage, with less than one drop per minute (0.07 cc/min), thereby enhancing system reliability and efficiency. The valve's construction incorporates Sun's floating style design which helps prevent internal parts from binding due to excessive installation torque or variations in cavity/cartridge machining. With dimensions accommodating a T5A cavity and requiring an installation torque between 45 - 50 lbf.ft (61 - 68 Nm), the CXEDLCV is versatile for integration into various setups without extensive modifications. The unit itself weighs approximately 0.40 lb (0.20 kg), making it lightweight yet durable enough for demanding applications. Additionally, it utilizes Viton seals (990203006) ensuring compatibility with a wide range of fluids and environmental conditions. Ideal for applications requiring precise fluid control and where space or existing system constraints are an issue, the CXEDLCV check valve is an essential component for enhancing system performance while providing reliable operation under high-pressure conditions.
The Sun Hydraulics CXEDLCV (CXEDLCV) is a high-performance hydraulic check valve designed for robust and efficient operation in various hydraulic systems. This valve features a freeflow, side-to-nose configuration, allowing free flow from inlet port 2 to outlet port 1 while blocking flow in the opposite direction. It is specifically engineered to address issues in existing circuits with incorrect manifold drillings, serving as a circuit saver by offering an alternative flow path. The CXEDLCV operates under a maximum pressure of 5000 psi (350 bar) at both ports and supports a flow capacity of up to 30 gpm (120 L/min). Notably, this model ensures minimal leakage, with less than one drop per minute (0.07 cc/min), thereby enhancing system reliability and efficiency. The valve's construction incorporates Sun's floating style design which helps prevent internal parts from binding due to excessive installation torque or variations in cavity/cartridge machining. With dimensions accommodating a T5A cavity and requiring an installation torque between 45 - 50 lbf.ft (61 - 68 Nm), the CXEDLCV is versatile for integration into various setups without extensive modifications. The unit itself weighs approximately 0.40 lb (0.20 kg), making it lightweight yet durable enough for demanding applications. Additionally, it utilizes Viton seals (990203006) ensuring compatibility with a wide range of fluids and environmental conditions. Ideal for applications requiring precise fluid control and where space or existing system constraints are an issue, the CXEDLCV check valve is an essential component for enhancing system performance while providing reliable operation under high-pressure conditions.
Free-flow, side-to-nose check valves are on/off circuit components that allow free flow from the inlet (port 2) to the outlet (port 1) and block flow in the opposite direction.
- Two-port check valves share the same cavity for a given frame size, however, pay close attention as flow paths may be in opposite directions.
- These check valves are considered circuit savers for existing circuits where manifold drillings are incorrect. The capacity of side-to-nose (port 2 to port 1) 2-port check valves is approximately 30% less than preferred models with a nose-to-side (port 1 to port 2) flow path.
- Check valves offer extremely low leakage rates with a maximum leakage of less than 1 drop per minute (0,07 cc/min).
- Will accept 5000 psi (350 bar) at ports 1 and 2.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-5A |
| Series | 2 |
| Capacity | 30 gpm120 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 1 drops/min.0,07 cc/min. |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-203-006 |
Show FAQ