SUN HYDRAULICS
CXEDXFV
$46.36 USD
- SUN HYDRAULICS
- Material:CXEDXFV
- Model:CXED-XFV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CXEDXFV (CXEDXFV) is a high-performance hydraulic check valve designed for efficient flow control in hydraulic systems. This two-port check valve allows free flow from the inlet port 2 to the outlet port 1 while blocking flow in the opposite direction, making it a critical component for applications requiring one-way flow. The CXEDXFV is specifically engineered to address circuit issues, such as incorrect manifold drillings, by serving as a circuit saver in existing systems. With a capacity of 30 gallons per minute (120 liters per minute) and an ability to handle maximum operating pressures up to 5000 psi (350 bar), the CXEDXFV is robust and versatile for various hydraulic applications. It features extremely low leakage rates, with a maximum of less than one drop per minute (0.07 cc/min), ensuring efficient operation and minimal fluid loss. The valve's construction incorporates Sun's floating style design which minimizes internal parts binding\u2014a common issue caused by excessive installation torque or cavity/cartridge machining variations. Designed with a T5A cavity and belonging to Series 2, this model has specific installation requirements including a valve hex size of 1-1/8 inches (28.6 mm) and an installation torque between 45 - 50 lbf ft (61 - 68 Nm). The lightweight design of the valve (.40 lb or 0.20 kg) adds minimal weight to hydraulic assemblies, facilitating ease of integration and maintenance. Additionally, it utilizes Viton seals (990203006) for enhanced durability and chemical resistance in harsh environments. This combination of features makes the CXEDXFV an excellent choice for optimizing hydraulic circuit performance while providing reliable operation across various conditions.
The Sun Hydraulics CXEDXFV (CXEDXFV) is a high-performance hydraulic check valve designed for efficient flow control in hydraulic systems. This two-port check valve allows free flow from the inlet port 2 to the outlet port 1 while blocking flow in the opposite direction, making it a critical component for applications requiring one-way flow. The CXEDXFV is specifically engineered to address circuit issues, such as incorrect manifold drillings, by serving as a circuit saver in existing systems. With a capacity of 30 gallons per minute (120 liters per minute) and an ability to handle maximum operating pressures up to 5000 psi (350 bar), the CXEDXFV is robust and versatile for various hydraulic applications. It features extremely low leakage rates, with a maximum of less than one drop per minute (0.07 cc/min), ensuring efficient operation and minimal fluid loss. The valve's construction incorporates Sun's floating style design which minimizes internal parts binding\u2014a common issue caused by excessive installation torque or cavity/cartridge machining variations. Designed with a T5A cavity and belonging to Series 2, this model has specific installation requirements including a valve hex size of 1-1/8 inches (28.6 mm) and an installation torque between 45 - 50 lbf ft (61 - 68 Nm). The lightweight design of the valve (.40 lb or 0.20 kg) adds minimal weight to hydraulic assemblies, facilitating ease of integration and maintenance. Additionally, it utilizes Viton seals (990203006) for enhanced durability and chemical resistance in harsh environments. This combination of features makes the CXEDXFV an excellent choice for optimizing hydraulic circuit performance while providing reliable operation across various conditions.
Free-flow, side-to-nose check valves are on/off circuit components that allow free flow from the inlet (port 2) to the outlet (port 1) and block flow in the opposite direction.
- Two-port check valves share the same cavity for a given frame size, however, pay close attention as flow paths may be in opposite directions.
- These check valves are considered circuit savers for existing circuits where manifold drillings are incorrect. The capacity of side-to-nose (port 2 to port 1) 2-port check valves is approximately 30% less than preferred models with a nose-to-side (port 1 to port 2) flow path.
- Check valves offer extremely low leakage rates with a maximum leakage of less than 1 drop per minute (0,07 cc/min).
- Will accept 5000 psi (350 bar) at ports 1 and 2.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-5A |
| Series | 2 |
| Capacity | 30 gpm120 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 1 drops/min.0,07 cc/min. |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-203-006 |