SUN HYDRAULICS
CXIBXFV
$299.13 USD
- SUN HYDRAULICS
- Material:CXIBXFV
- Model:CXIB-XFV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CXIBXFV (CXIBXFV) is a meticulously engineered sidetonose check valve designed to facilitate free flow from inlet port 2 to outlet port 1 while blocking the reverse flow. This valve features a Delrin seat, making it ideal for medium-pressure systems that are exposed to dirty conditions but not high flows or temperatures. The CXIBXFV is tailored for applications where manifold drillings may have been inaccurately executed, serving as a circuit saver by correcting these errors without the need for extensive system modifications. With a capacity of 120 gpm (480 L/min) and a maximum operating pressure of 3000 psi (210 bar), this check valve is well-suited for various hydraulic applications requiring reliable, unidirectional flow control. It boasts an extremely low leakage rate, with maximum leakage capped at less than one drop per minute (0.07 cc/min), ensuring efficient and clean operations. The valve's construction incorporates Sun's floating style design which minimizes internal part binding due to excessive installation torque or cavity/cartridge machining variations. This model uses a T18A cavity and belongs to the Series 4 line of Sun Hydraulics' products. It requires an installation torque between 350 \u2013 375 lbf ft (474 \u2013 508 Nm) and has a hex size of 1-5/8 inches (41.3 mm). Weighing in at approximately 2.10 lb (0.95 kg), the CXIBXFV also supports Viton seals and cartridges, enhancing its adaptability and resilience in various hydraulic setups. This check valve stands out as an effective solution for enhancing system reliability and correcting installation discrepancies in hydraulic circuits.
The Sun Hydraulics CXIBXFV (CXIBXFV) is a meticulously engineered sidetonose check valve designed to facilitate free flow from inlet port 2 to outlet port 1 while blocking the reverse flow. This valve features a Delrin seat, making it ideal for medium-pressure systems that are exposed to dirty conditions but not high flows or temperatures. The CXIBXFV is tailored for applications where manifold drillings may have been inaccurately executed, serving as a circuit saver by correcting these errors without the need for extensive system modifications. With a capacity of 120 gpm (480 L/min) and a maximum operating pressure of 3000 psi (210 bar), this check valve is well-suited for various hydraulic applications requiring reliable, unidirectional flow control. It boasts an extremely low leakage rate, with maximum leakage capped at less than one drop per minute (0.07 cc/min), ensuring efficient and clean operations. The valve's construction incorporates Sun's floating style design which minimizes internal part binding due to excessive installation torque or cavity/cartridge machining variations. This model uses a T18A cavity and belongs to the Series 4 line of Sun Hydraulics' products. It requires an installation torque between 350 \u2013 375 lbf ft (474 \u2013 508 Nm) and has a hex size of 1-5/8 inches (41.3 mm). Weighing in at approximately 2.10 lb (0.95 kg), the CXIBXFV also supports Viton seals and cartridges, enhancing its adaptability and resilience in various hydraulic setups. This check valve stands out as an effective solution for enhancing system reliability and correcting installation discrepancies in hydraulic circuits.
Free-flow, side-to-nose check valves are on/off circuit components that allow free flow from the inlet (port 2) to the outlet (port 1) and block flow in the opposite direction.
- The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
- Two-port check valves share the same cavity for a given frame size, however, pay close attention as flow paths may be in opposite directions.
- These check valves are considered circuit savers for existing circuits where manifold drillings are incorrect. The capacity of side-to-nose (port 2 to port 1) 2-port check valves is approximately 30% less than preferred models with a nose-to-side (port 1 to port 2) flow path.
- Check valves offer extremely low leakage rates with a maximum leakage of less than 1 drop per minute (0,07 cc/min).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-18A |
| Series | 4 |
| Capacity | 120 gpm480 L/min. |
| Maximum Operating Pressure | 3000 psi210 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 1 drops/min.0,07 cc/min. |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Model Weight | 2.10 lb0,95 kg |
| Seal kit - Cartridge | Viton: 990-018-006 |
Show FAQ