SUN HYDRAULICS
DNDYDXV924
$316.61 USD
- SUN HYDRAULICS
- Material:DNDYDXV924
- Model:DNDY-DXV@924
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics DNDYDXV924 (DNDYDXV924) is a solenoid-operated 6-way, 2-position cartridge valve designed for directing hydraulic flow between two separate circuits. In its de-energized state, it connects ports P and T to the first circuit, while energizing it switches the connection to the second circuit. This valve features a fatigue-rated solenoid tube assembly capable of handling service pressures up to 5000 psi (350 bar). It is direct actuated, requiring no minimum hydraulic pressure for operation, and offers several manual override options with a mechanical life expectancy of approximately 7,000 cycles. The valve employs a wet armature design, exposing the working fluid to coil-generated heat which can affect certain fluids over time. It provides various coil termination and voltage options with surge protection capabilities, and its magnetic design ensures high efficiency with reliable valve shifting. Coils are interchangeable with other Sun Series 1 products and can be mounted in either direction. The valve's construction minimizes internal binding risks due to installation torque or machining variations. It fits into cavity T-61A, has a capacity of 5 gpm (20 L/min), a typical response time of 50 ms, and handles maximum leakage at specified conditions up to 5 in\u00b3/min (80 cc/min). The switching frequency reaches up to 15,000 cycles per hour. Manual override requires a force of approximately 5 lbs/1000 psi at Port 1 and features a stroke length of .10 inches (2.5 mm). The solenoid tube has a diameter of .75 inches (19 mm), and the valve hex size is .78 inches (22.2 mm), requiring an installation torque between 30-35 lbf.ft (41-47 Nm). The model weighs .60 lb (.30 kg) and comes with Viton seal kits for both cartridge and coil applications.
The Sun Hydraulics DNDYDXV924 (DNDYDXV924) is a solenoid-operated 6-way, 2-position cartridge valve designed for directing hydraulic flow between two separate circuits. In its de-energized state, it connects ports P and T to the first circuit, while energizing it switches the connection to the second circuit. This valve features a fatigue-rated solenoid tube assembly capable of handling service pressures up to 5000 psi (350 bar). It is direct actuated, requiring no minimum hydraulic pressure for operation, and offers several manual override options with a mechanical life expectancy of approximately 7,000 cycles. The valve employs a wet armature design, exposing the working fluid to coil-generated heat which can affect certain fluids over time. It provides various coil termination and voltage options with surge protection capabilities, and its magnetic design ensures high efficiency with reliable valve shifting. Coils are interchangeable with other Sun Series 1 products and can be mounted in either direction. The valve's construction minimizes internal binding risks due to installation torque or machining variations. It fits into cavity T-61A, has a capacity of 5 gpm (20 L/min), a typical response time of 50 ms, and handles maximum leakage at specified conditions up to 5 in\u00b3/min (80 cc/min). The switching frequency reaches up to 15,000 cycles per hour. Manual override requires a force of approximately 5 lbs/1000 psi at Port 1 and features a stroke length of .10 inches (2.5 mm). The solenoid tube has a diameter of .75 inches (19 mm), and the valve hex size is .78 inches (22.2 mm), requiring an installation torque between 30-35 lbf.ft (41-47 Nm). The model weighs .60 lb (.30 kg) and comes with Viton seal kits for both cartridge and coil applications.
This solenoid-operated 6-way, 2-position cartridge is a direct-acting, balanced spool valve. The typical use for this valve is to select between two separate circuits. The de-energized condition connects P and T to the first circuit and when energized connects P and T to the second circuit.
- The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
- This valve is direct actuated and requires no minimum hydraulic pressure for operation.
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control assembly has a mechanical life expectancy of approximately 7,000 cycles.
- This cartridge has several manual override choices, including no manual override. See the CONFIGURATION section. Please note: Manual override functionality is not compatible with weatherized coils.
- This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
- A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
- The solenoid's unique magnetic design results in a high efficiency solenoid, yielding high spool actuating force per Watt expended, leading to reliable valve shifting.
- Coils are interchangeable with other Sun Series 1 solenoid products and can be mounted on the tube in either direction.
- Coil connector options offer ratings up to IP69K. See individual coil product pages for details. Additional weatherized coils and kits are available for more complete environmental protection.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-61A |
| Series | 1 |
| Capacity | 5 gpm20 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 50 ms50 ms |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 5 in³/min.@3000 psi80 cc/min.@210 bar |
| Switching Frequency | 15000 cycles/hr15000 cycles/hr |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-461-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ