SUN HYDRAULICS
DPCMCAN
$170.36 USD
- SUN HYDRAULICS
- Material:DPCMCAN
- Model:DPCM-CAN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics DPCMCAN (Material Number: DPCMCAN) is a normally open, pilot-operated, 2-way directional cartridge valve designed for moderate flow circuits. It can function independently or be used to actuate larger pilot-operated directional cartridges or logic cartridges. The valve operates by shifting when the pressure differential between port 1 and port 4 surpasses the specified setting, with the option to block port 4 to prevent shifting. Port 3 serves as a work port in the system. This model is interchangeable with direct-acting versions, sharing cavity and flow path compatibility. The maximum pressure at port 3 should not exceed 3000 psi (210 bar) due to fatigue strength limits. The valve incorporates Sun's floating style construction to minimize internal binding risks due to installation torque or machining variations. The DPCMCAN fits a T-22A cavity and belongs to Series 2 with a capacity of up to 15 gpm (60 L/min). Factory pressure settings are established at a flow rate of 4 gpm (15 L/min), and it can operate at a maximum pressure of 5000 psi (350 bar). Control pilot flow ranges from 10-15 in\u00b3/min (0.16-0.25 L/min), while maximum valve leakage at 110 SUS (24 cSt) is limited to 1 in\u00b3/min per 1000 psi (15 cc/min per 70 bar). For adjustment, turning clockwise increases the setting by up to five full turns. The valve has a hex size of 1-1/8 inches (28.6 mm) and requires an installation torque of between 45-50 lbf ft (61-68 Nm). An internal hex size for the adjustment screw is set at 5/32 inches (4 mm), with locknut hex size at 9/16 inches (15 mm) and torque requirements of between 80-90 lbf in.
The Sun Hydraulics DPCMCAN (Material Number: DPCMCAN) is a normally open, pilot-operated, 2-way directional cartridge valve designed for moderate flow circuits. It can function independently or be used to actuate larger pilot-operated directional cartridges or logic cartridges. The valve operates by shifting when the pressure differential between port 1 and port 4 surpasses the specified setting, with the option to block port 4 to prevent shifting. Port 3 serves as a work port in the system. This model is interchangeable with direct-acting versions, sharing cavity and flow path compatibility. The maximum pressure at port 3 should not exceed 3000 psi (210 bar) due to fatigue strength limits. The valve incorporates Sun's floating style construction to minimize internal binding risks due to installation torque or machining variations. The DPCMCAN fits a T-22A cavity and belongs to Series 2 with a capacity of up to 15 gpm (60 L/min). Factory pressure settings are established at a flow rate of 4 gpm (15 L/min), and it can operate at a maximum pressure of 5000 psi (350 bar). Control pilot flow ranges from 10-15 in\u00b3/min (0.16-0.25 L/min), while maximum valve leakage at 110 SUS (24 cSt) is limited to 1 in\u00b3/min per 1000 psi (15 cc/min per 70 bar). For adjustment, turning clockwise increases the setting by up to five full turns. The valve has a hex size of 1-1/8 inches (28.6 mm) and requires an installation torque of between 45-50 lbf ft (61-68 Nm). An internal hex size for the adjustment screw is set at 5/32 inches (4 mm), with locknut hex size at 9/16 inches (15 mm) and torque requirements of between 80-90 lbf in.
Normally open, pilot-operated, 2-way directional cartridges are switching devices typically used in moderate flow circuits. They can be used by themselves or to actuate larger pilot-operated directional cartridges or logic cartridges. The valve shifts when the pressure differential between port 1 and port 4 exceeds the setting.
- Port 4 can be blocked to prevent the valve from shifting.
- Port 3 can be used as a work port.
- Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
- Pressure at port 4 is directly additive to the setting of the valve.
- This valve is not bistable; it is capable of modulating between the two positions shown.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
- When pilot pressure exceeds the valve setting, pilot flow may be a consideration. See performance curves for pilot consumption vs. load pressure above the valve setting. If this is a problem, the direct acting version of this valve would be a solution.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-22A |
| Series | 2 |
| Capacity | 15 gpm60 L/min. |
| Factory Pressure Settings Established at | 4 gpm15 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 1 in³/min.@1000 psi15 cc/min.@70 bar |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-022-006 |
Show FAQ