***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics DPCNKEN (DPCNKEN) is a normally closed, pilot-operated, 2-way directional cartridge valve designed for moderate flow circuits. This versatile valve can function independently or in conjunction with larger pilot-operated directional or logic cartridges. It operates by shifting when the pressure differential between port 1 and port 4 surpasses the preset threshold, with the option to block port 4 to prevent shifting. Port 3 serves as a work port, with a maximum allowable pressure of 3000 psi due to fatigue strength limitations. The DPCNKEN is capable of modulating between two positions and features interchangeable direct-acting and pilot-operated versions that fit the same cavities and flow paths. With a cavity size of T22A and a capacity of 15 gpm (60 L/min), this valve supports maximum operating pressures up to 5000 psi (350 bar). Factory pressure settings are established at 4 gpm (15 L/min), while control pilot flow ranges from 10 to 15 in\u00b3/min (0.16 to 0.25 L/min). The valve offers minimal leakage at maximum levels of 1 in\u00b3/min at 1000 psi (15 cc/min at 70 bar). Adjustment for increasing settings requires up to five clockwise turns, with specific torque requirements for installation and locknut adjustments. The DPCNKEN incorporates Sun's floating style construction, reducing internal binding risks due to installation torque or machining variations. This robust design ensures reliable performance across various hydraulic applications while maintaining ease of adjustment and stability under varying conditions.
The Sun Hydraulics DPCNKEN (DPCNKEN) is a normally closed, pilot-operated, 2-way directional cartridge valve designed for moderate flow circuits. This versatile valve can function independently or in conjunction with larger pilot-operated directional or logic cartridges. It operates by shifting when the pressure differential between port 1 and port 4 surpasses the preset threshold, with the option to block port 4 to prevent shifting. Port 3 serves as a work port, with a maximum allowable pressure of 3000 psi due to fatigue strength limitations. The DPCNKEN is capable of modulating between two positions and features interchangeable direct-acting and pilot-operated versions that fit the same cavities and flow paths. With a cavity size of T22A and a capacity of 15 gpm (60 L/min), this valve supports maximum operating pressures up to 5000 psi (350 bar). Factory pressure settings are established at 4 gpm (15 L/min), while control pilot flow ranges from 10 to 15 in\u00b3/min (0.16 to 0.25 L/min). The valve offers minimal leakage at maximum levels of 1 in\u00b3/min at 1000 psi (15 cc/min at 70 bar). Adjustment for increasing settings requires up to five clockwise turns, with specific torque requirements for installation and locknut adjustments. The DPCNKEN incorporates Sun's floating style construction, reducing internal binding risks due to installation torque or machining variations. This robust design ensures reliable performance across various hydraulic applications while maintaining ease of adjustment and stability under varying conditions.
Normally closed, pilot-operated, 2-way directional cartridges are switching devices typically used in moderate flow circuits. They can be used by themselves or to actuate larger pilot operated directional cartridges or logic cartridges. The valve shifts when the pressure differential between port 1 and port 4 exceeds the setting.
- Port 4 can be blocked to prevent the valve from shifting.
- Port 3 can be used as a work port.
- Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
- Pressure at port 4 is directly additive to the setting of the valve.
- This valve is not bistable; it is capable of modulating between the two positions shown.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
- When pilot pressure exceeds the valve setting, pilot flow may be a consideration. See performance curves for pilot consumption vs. load pressure above the valve setting. If this is a problem, the direct acting version of this valve would be a solution.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-22A |
| Series | 2 |
| Capacity | 15 gpm60 L/min. |
| Factory Pressure Settings Established at | 4 gpm15 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 1 in³/min.@1000 psi15 cc/min.@70 bar |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-022-006 |