SUN HYDRAULICS
DSEYXDN
$159.24 USD
- SUN HYDRAULICS
- Material:DSEYXDN
- Model:DSEY-XDN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics DSEYXDN (DSEYXDN) is a vent-to-shift diverter valve designed as a 2-position, 3-way cartridge that is normally open from port 3 to port 4. When port 1 is vented, the pressure differential between port 3 and port 1 surpasses the spring force, causing the valve to shift and connect port 3 to port 2. This valve is not bistable and can modulate between these two positions. The vent flow out of port 1 is pressure compensated, requiring a pressure source at port 3 relative to port 1 for shifting. It can be used in pairs for selecting between two motors or pumps and allows one pilot valve to vent multiple diverter valves if blocking checks are installed at each diverter\u2019s port 1. Without blocking checks, there will be interaction between high and low-pressure legs of the circuit. The self-cleaning vent-to-shift function makes it insensitive to contamination, while the hardened spool and sleeve ensure consistent low spool leakage rates and excellent wear characteristics. The Sun floating style construction minimizes internal part binding due to excessive installation torque or cavity/cartridge machining variations. It fits into a T-32A cavity, belongs to series 2, has a capacity of up to 30 gpm (120 L/min), and can handle a maximum operating pressure of up to 5000 psi (350 bar). The nominal vent flow is rated at .23 in\u00b3/min (.38 L/min). Installation requires a torque of between 45-50 lbf ft (61-68 Nm), with the model weighing .70 lb (.30 kg). Viton seal kits are available under part number 990032006 for maintenance purposes.
The Sun Hydraulics DSEYXDN (DSEYXDN) is a vent-to-shift diverter valve designed as a 2-position, 3-way cartridge that is normally open from port 3 to port 4. When port 1 is vented, the pressure differential between port 3 and port 1 surpasses the spring force, causing the valve to shift and connect port 3 to port 2. This valve is not bistable and can modulate between these two positions. The vent flow out of port 1 is pressure compensated, requiring a pressure source at port 3 relative to port 1 for shifting. It can be used in pairs for selecting between two motors or pumps and allows one pilot valve to vent multiple diverter valves if blocking checks are installed at each diverter\u2019s port 1. Without blocking checks, there will be interaction between high and low-pressure legs of the circuit. The self-cleaning vent-to-shift function makes it insensitive to contamination, while the hardened spool and sleeve ensure consistent low spool leakage rates and excellent wear characteristics. The Sun floating style construction minimizes internal part binding due to excessive installation torque or cavity/cartridge machining variations. It fits into a T-32A cavity, belongs to series 2, has a capacity of up to 30 gpm (120 L/min), and can handle a maximum operating pressure of up to 5000 psi (350 bar). The nominal vent flow is rated at .23 in\u00b3/min (.38 L/min). Installation requires a torque of between 45-50 lbf ft (61-68 Nm), with the model weighing .70 lb (.30 kg). Viton seal kits are available under part number 990032006 for maintenance purposes.
This vent-to-shift diverter valve is a 2-position, 3-way cartridge that is normally open from port 3 to port 4. When port 1 is vented, the pressure differential between port 3 and port 1 exceeds the spring force causing the valve to shift, thereby connecting port 3 to port 2.
- This valve is not bistable; it is capable of modulating between the two positions shown.
- Vent flow out of port 1 is pressure compensated and is listed in Technical Data.
- There must be a pressure source at port 3, relative to port 1, to shift the valve.
- One application of this valve is to be used in pairs to select between 2 motors or pumps.
- One pilot valve may be used to vent multiple diverter valves if blocking checks are used at port 1 of each diverter. If blocking checks are not used there will be interaction between high and low pressure legs of the circuit.
- The vent-to-shift function is self cleaning and therefore insensitive to contamination.
- Hardened spool and sleeve provide consistent and low spool leakage rates and excellent wear characteristics.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-32A |
| Series | 2 |
| Capacity | 30 gpm120 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Nominal Vent Flow | 23 in³/min.0,38 L/min. |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Model Weight | .70 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-032-006 |