SUN HYDRAULICS
FMDADAN812
$304.89 USD
- SUN HYDRAULICS
- Material:FMDADAN812
- Model:FMDA-DAN@812
- Summary:Cartridge
Quantity in stock: 0
The Sun Hydraulics FMDADAN812 (FMDADAN812) is a versatile 3-way, electro-proportional throttle valve designed for precise flow control in hydraulic systems. This valve features a meter-in configuration and operates with a closed transition between positions. In its unenergized state, the supply is blocked at port 1, and port 2 is drained to tank at port 3. When energized, the coil exerts a closing force on the spool, creating a metering orifice from port 1 to port 2 that is proportional to the coil command current. The valve is self-compensating in this direction and can be pressure compensated with an external compensator for enhanced flow control accuracy. The FMDADAN812 is suitable for circuits with separate tank passages, such as cushion lock circuits. It allows for flexible flow range selection without requiring custom spools by using two FMDA valves to create a meter-in/meter-out 3-position, 4-way configuration. While flow from port 2 to port 3 is not proportional and limited to approximately 1.5 gpm (6 L/min), this limitation enhances resolution and capacity. With all ports rated for up to 5000 psi (350 bar), the valve incorporates Sun's floating style construction to prevent internal part binding due to excessive installation torque or machining variations. The valve's manual override options include temporary actuation detents and a momentary-twist mechanism for ease of use. For optimal performance, an amplifier with current sensing and adjustable dither between 100-250 Hz should be used. The solenoid coils are interchangeable with other Sun solenoid-operated valves and can be mounted in either direction on the tube. This robust design ensures reliable operation across various applications requiring precise hydraulic flow control.
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.
- Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 9 gpm34 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-411-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ