SUN HYDRAULICS
FMDADBV512
$304.69 USD
- SUN HYDRAULICS
- Material:FMDADBV512
- Model:FMDA-DBV@512
- Summary:Cartridge
Quantity in stock: 0
The Sun Hydraulics FMDADBV512 (Material Number: FMDADBV512) is a 3-way, meter-in, electro-proportional throttle valve designed for precision flow control in hydraulic systems. When unenergized, the supply at port 1 is blocked, and port 2 drains to the tank at port 3. Energizing the coil applies a closing force on the spool, creating a metering orifice from port 1 to port 2 that adjusts proportionally to the coil command current. This valve inherently self-compensates in the 1 to 2 direction and can be pressure compensated with an external modulating element for enhanced flow control accuracy. It is specifically designed for use in circuits with a separate passage to the tank, such as cushion lock circuits, and can be paired with another FMDA valve to create a meter-in-meter-out three-position four-way configuration. The flow capacity from port 2 to port 3 is limited to approximately 1.5 gpm (6 L/min) to improve resolution and capacity. All ports can handle pressures up to 5000 psi (350 bar). The valve includes interchangeable coils compatible with other Sun solenoid-operated valves and features manual override options such as momentary-twist override \"E\" for temporary actuation. For optimal performance, an amplifier with current sensing and adjustable dither between 100-250 Hz is recommended. The valve's construction minimizes internal part binding risks due to excessive installation torque or machining variations. Additional specifications include a cavity size of T-11A, series number of 1, and a maximum flow capacity of up to 9 gpm (34 L/min). The manual override requires a force of approximately 5 lbs/1000 psi at Port 1, with an override stroke of .10 inches (2.5 mm). The model weighs around 1.10 lbs (0.50 kg) when equipped with a coil and requires Viton seal kits for maintenance.
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.
- Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 9 gpm34 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-411-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ