SUN HYDRAULICS
FMDALAV612
$306.38 USD
- SUN HYDRAULICS
- Material:FMDALAV612
- Model:FMDA-LAV@612
- Summary:Cartridge
Quantity in stock: 0
The Sun Hydraulics FMDALAV612 (FMDALAV612) is a versatile 3-way, meter-in, electro-proportional throttle valve designed for precise hydraulic flow control. In its unenergized state, this valve blocks supply at port 1 while draining port 2 to the tank at port 3. When the coil is energized, it applies a closing force on the spool, creating a metering orifice from port 1 to port 2 that is proportional to the coil command current. It self-compensates in this direction and can provide pressure-compensated flow control with an external compensator. The flow from port 2 to port 3 is not proportional and is limited to approximately 1.5 gpm (6 L/min) for enhanced resolution and capacity. Ideal for circuits with separate tank passages like cushion lock circuits, two FMDA valves can be used together to form a meter-in-meter-out 3-position, 4-way configuration. The valve features closed transition between positions and allows users to select existing flow ranges without requiring special spools by utilizing two 3-way valves to create a 4-way system. For enhanced accuracy in flow control across various flows and pressures, an external modulating logic element can be integrated. The valve supports all ports up to a pressure of 5000 psi (350 bar) and offers manual override options with different control assemblies having a mechanical life expectancy of about 7,000 cycles. Coils are interchangeable with other Sun solenoid-operated valves for flexible installation. Optimal performance can be achieved using an amplifier with current sensing and adjustable dither between 100-250 Hz. The design incorporates Sun's floating style construction to minimize internal binding due to installation or machining variations. This valve fits into cavity T-11A, has a series rating of one, and offers a capacity of up to nine gpm (34 L/min). It includes Viton seal kits for both cartridge and coil components ensuring reliable operation under demanding conditions.
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.
- Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 9 gpm34 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-411-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ