The Sun Hydraulics FMDATAV2B12A (FMDATAV2B12A) is a 3-way, meter-in, electro-proportional throttle valve designed for precise flow control in hydraulic circuits. This valve features a unique flow path that remains blocked at port 1 and drains to the tank at port 3 when unenergized. When the coil is energized, it creates a metering orifice in the 1 to 2 direction proportional to the coil command current. The valve self-compensates in this direction and can provide pressure-compensated flow control with an external compensator. Flow in the 2 to 3 direction is non-proportional with a capacity of about 1.5 gpm (6 L/min), optimized for resolution and capacity. It's ideal for circuits like cushion lock systems where separate tank passages are required. This model can be part of a meter-in/meter-out, 3-position, 4-way configuration when used with another FMDA valve, allowing users to select existing flow ranges without custom spools. The valve supports pressure compensation through an external modulating logic element for improved accuracy over various flows and pressures. It operates efficiently at pressures up to 5000 psi (350 bar) across all ports. Equipped with manual override options, including temporary actuation detents and momentary-twist mechanisms, it offers flexibility in operation. The solenoid coils are interchangeable with other Sun full-flow valves and can be mounted bidirectionally on the tube. For optimal performance, pairing with an amplifier featuring current sensing and adjustable dither between 100-250 Hz is recommended. Constructed using Sun's floating-style design, it minimizes internal binding risks due to installation torque or machining variations. With a capacity of up to 9 gpm (34 L/min) and specific installation requirements, this valve is robust yet precise for demanding applications requiring reliable hydraulic control.
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.
- Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 9 gpm34 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-411-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ