SUN HYDRAULICS
FMDATAV512
$318.59 USD
- SUN HYDRAULICS
- Material:FMDATAV512
- Model:FMDA-TAV@512
- Summary:Cartridge
Quantity in stock: 0
The Sun Hydraulics FMDATAV512 (FMDATAV512) is an advanced 3-way, meter-in, electro-proportional throttle valve designed for precise flow control in hydraulic circuits. This valve features a unique flow path where, when unenergized, the supply is blocked at port 1 and port 2 drains to tank at port 3. Upon energizing the coil, a closing force is applied to the spool, forming a metering orifice in the 1 to 2 direction proportional to the coil command current. The valve self-compensates in this direction and can achieve pressure-compensated flow control with an external compensator. Flow from port 2 to port 3 is non-proportional and limited to approximately 1.5 gpm (6 L/min) for enhanced resolution and capacity. The FMDATAV512 is ideally used in circuits with separate tank passages, such as cushion lock circuits. When paired with another FMDA valve, it can create a meter-in/meter-out configuration for a three-position, four-way operation. The transition between positions remains closed, allowing users to select existing flow ranges without needing custom spools. The valve supports pressure compensation through external modulating logic elements like LRCXHN for bypass circuits or LPCXHN for restrictive circuits. All ports of this valve can handle pressures up to 5000 psi (350 bar). It incorporates Sun's floating style construction to reduce internal binding risks due to installation torque or machining variations. For optimal performance, use an amplifier with adjustable dither between 100-250 Hz and current sensing capabilities. The manual override options provide temporary actuation with a mechanical life expectancy of about 7,000 cycles. The FMDATAV512 fits into cavity T-11A and has a capacity of up to 9 gpm (34 L/min), making it versatile for various hydraulic applications requiring precise flow management.
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.
- Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 9 gpm34 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-411-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ