SUN HYDRAULICS
FMDATDV2C24V
$597.47 USD
- SUN HYDRAULICS
- Material:FMDATDV2C24V
- Model:FMDA-TDV@2C24V
- Summary:Cartridge
Quantity in stock: 0
The Sun Hydraulics FMDATDV2C24V (FMDATDV2C24V) is a sophisticated 3-way, electro-proportional throttle valve designed for precise flow control applications. This valve features a meter-in configuration where, in its unenergized state, the supply is blocked at port 1 and port 2 drains to tank at port 3. When the coil is energized, it exerts a closing force on the spool, creating a proportional metering orifice from port 1 to port 2 based on the coil command current. The valve self-compensates in this direction and can be pressure compensated with an external modulating logic element for enhanced flow control accuracy. Flow from port 2 to port 3 is limited to approximately 1.5 gpm (6 L/min) to improve resolution and capacity. Ideal for circuits requiring separate tank passages like cushion lock circuits, two FMDA valves can be combined with such a circuit to form a meter-in-meter-out, three-position, four-way configuration. The transition between positions remains closed, and existing flow ranges can be selected without needing custom spools by using two three-way valves. All ports are rated for up to 5000 psi (350 bar), ensuring robust performance under high-pressure conditions. The valve incorporates Sun's floating style construction to reduce potential internal part binding due to excessive installation torque or cavity-cartridge machining variations. For optimal performance, an amplifier with current sensing and adjustable dither (100-250 Hz) is recommended. The manual override options include a momentary twist mechanism that allows temporary actuation by twisting the override clockwise by 90 degrees. Additionally, the valve's solenoid coils are interchangeable with other Sun solenoid-operated valves and can be mounted in either direction on the tube.
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.
- Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 9 gpm34 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-411-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ