SUN HYDRAULICS
FMDAXAN2F12V
$512.19 USD
- SUN HYDRAULICS
- Material:FMDAXAN2F12V
- Model:FMDA-XAN@2F12V
- Summary:Cartridge
Quantity in stock: 0
The Sun Hydraulics FMDAXAN2F12V (Material Number: FMDAXAN2F12V) is a 3-way, meter-in, electro-proportional throttle valve designed for precision flow control in hydraulic systems. In its unenergized state, this valve blocks the supply at port 1 while draining port 2 to tank at port 3. When the coil is energized, it creates a metering orifice in the 1 to 2 direction proportional to the coil command current, allowing for self-compensated flow control. The valve requires an external compensator for pressure-compensated flow control and can achieve about 1.5 gpm (6 L/min) capacity in the 2 to 3 direction, although this flow is not proportional and is limited for enhanced resolution and capacity. This valve is ideal for circuits with separate passages to tank, such as cushion lock circuits, and can be combined with another FMDA valve to form a meter-in-meter-out configuration in a three-position four-way setup. It features pressure compensation via an external modulating logic element and accepts all ports up to 5000 psi (350 bar). The manual override options include detent mechanisms for temporary actuation with an approximate mechanical life expectancy of 7,000 cycles. Additionally, the momentary-twist override allows manual shifting by twisting clockwise by 90 degrees. The Sun Hydraulics FMDAXAN2F12V incorporates floating style construction to minimize internal part binding due to excessive installation torque or machining variations. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve's cavity type is T-11A, series type is 1, with a capacity of up to 9 gpm (34 L/min). It has specific installation requirements including a torque range of 30-35 lbf ft (41-47 Nm), ensuring reliable operation in hydraulic applications requiring precise flow regulation.
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.
- Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 9 gpm34 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-411-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ