The Sun Hydraulics FMDAXAV524 (FMDAXAV524) is a 3-way, meter-in, electro-proportional throttle valve designed for precise flow control in hydraulic circuits. In its unenergized state, the valve blocks the supply at port 1 and drains port 2 to the tank at port 3. When energized, it generates a closing force on the spool to create a metering orifice from port 1 to port 2, which is proportional to the coil command current. This self-compensating valve can be used for pressure-compensated flow control with an external compensator. However, flow from port 2 to port 3 is limited to about 1.5 gpm (6 L/min) for increased resolution and capacity. The valve is suitable for circuits with separate tank passages, such as cushion lock circuits, and can be combined with another FMDA valve to form a meter-in/meter-out 3-position, 4-way configuration. The FMDAXAV524 accepts up to 5000 psi (350 bar) across all ports and features a manual override option with approximately 7,000 cycles of mechanical life expectancy. Coils are interchangeable with other Sun solenoid-operated valves and can be mounted in either direction on the solenoid tube. For optimal performance, an amplifier with current sensing and adjustable dither (100-250 Hz) is recommended. The valve incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. Additional specifications include a cavity size of T-11A, series number of 1, and a capacity of up to 9 gpm (34 L/min). It has a maximum leakage rate of 2 in\u00b3/min at 1000 psi (30 cc/min at 70 bar), requires a manual override force of approximately 5 lbs/1000 psi (33 N/100 bar), and has an installation torque range of 30-35 lbf\u00b7ft (41-47 Nm). The model weighs approximately 1.10 lb (0.50 kg) when equipped with a coil and uses Viton seal kits for both cartridge and coil assemblies.
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.
- Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 9 gpm34 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-411-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |