SUN HYDRAULICS
FMDAXBV2B24A
$559.84 USD
- SUN HYDRAULICS
- Material:FMDAXBV2B24A
- Model:FMDA-XBV@2B24A
- Summary:Cartridge
Quantity in stock: 0
The Sun Hydraulics FMDAXBV2B24A (FMDAXBV2B24A) is a 3-way, meter-in, electro-proportional throttle valve designed for precise flow control in hydraulic systems. In its unenergized state, the supply is blocked at port 1 while port 2 drains to the tank at port 3. When the coil is energized, it generates a closing force on the spool, creating a metering orifice from port 1 to port 2 proportional to the coil command current. This valve self-compensates in the 1 to 2 direction and can be configured with an external compensator for pressure-compensated flow control. Flow from port 2 to port 3 is limited for increased resolution and capacity, with a maximum capacity of about 1.5 gpm (6 L/min). The valve is suitable for circuits with separate passages to the tank like cushion lock circuits and can be combined with another FMDA valve to create a meter-in-meter-out configuration. The FMDAXBV2B24A features Sun's floating style construction, reducing internal binding risks due to installation torque or machining variations. It accepts up to 5000 psi (350 bar) across all ports and has a maximum leakage rate of 2 in\u00b3/min at 1000 psi (30 cc/min at 70 bar). For manual operation, it requires an override force of approximately 5 lbs/1000 psi and has a stroke of .10 inches (2.5 mm). The valve's solenoid tube diameter measures .75 inches (19 mm), and it requires an installation torque between 30-35 lbf-ft (41-47 Nm). Weighing approximately 1.10 lb (0.50 kg) with the coil included, this model also includes interchangeable coils compatible with other Sun solenoid-operated valves. For optimal performance, using an amplifier with current sensing and adjustable dither is recommended; dither should be adjustable between 100-250 Hz. The valve can also incorporate external modulating logic elements for enhanced flow control accuracy over varied flows and pressures.
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.
- Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 9 gpm34 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-411-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ