SUN HYDRAULICS
FPCCEAN2D24A
$571.55 USD
- SUN HYDRAULICS
- Material:FPCCEAN2D24A
- Model:FPCC-EAN@2D24A
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPCCEAN2D24A (FPCCEAN2D24A) is a normally closed, electroproportional throttle valve designed for precise flow control in hydraulic systems. This valve is engineered to be spring-biased closed, with the coil generating an opening force on the spool proportional to the command current. This interaction between the coil and spring creates a metering orifice that adjusts its size based on the current input, allowing for accurate flow regulation. The valve supports full reverse flow from port 2 to port 1 under all conditions without requiring an external compensator when fully energized. It operates effectively at pressures up to 5000 psi and features low leakage levels when closed. The FPCCEAN2D24A is available in both normally open and normally closed configurations with three capacity ranges, making it versatile for various applications. It incorporates Sun's floating style construction, minimizing potential binding of internal parts due to excessive installation torque or machining variations. The interchangeable coils can be mounted in either direction on the solenoid tube, enhancing flexibility during installation. This model offers several manual override options, including choices with or without manual override capabilities. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither ranging from 100 to 250 Hz. The valve's mechanical components have a life expectancy of approximately 7,000 cycles, ensuring durability over prolonged use. Additionally, cartridges with EPDM seals are suited for systems utilizing phosphate ester fluids; however, exposure to petroleum-based fluids should be avoided as it may damage the seals. The FPCCEAN2D24A fits into a T-13A cavity and has a capacity of 10 gpm (40 L/min), making it suitable for various hydraulic applications requiring precise flow control solutions.
The Sun Hydraulics FPCCEAN2D24A (FPCCEAN2D24A) is a normally closed, electroproportional throttle valve designed for precise flow control in hydraulic systems. This valve is engineered to be spring-biased closed, with the coil generating an opening force on the spool proportional to the command current. This interaction between the coil and spring creates a metering orifice that adjusts its size based on the current input, allowing for accurate flow regulation. The valve supports full reverse flow from port 2 to port 1 under all conditions without requiring an external compensator when fully energized. It operates effectively at pressures up to 5000 psi and features low leakage levels when closed. The FPCCEAN2D24A is available in both normally open and normally closed configurations with three capacity ranges, making it versatile for various applications. It incorporates Sun's floating style construction, minimizing potential binding of internal parts due to excessive installation torque or machining variations. The interchangeable coils can be mounted in either direction on the solenoid tube, enhancing flexibility during installation. This model offers several manual override options, including choices with or without manual override capabilities. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither ranging from 100 to 250 Hz. The valve's mechanical components have a life expectancy of approximately 7,000 cycles, ensuring durability over prolonged use. Additionally, cartridges with EPDM seals are suited for systems utilizing phosphate ester fluids; however, exposure to petroleum-based fluids should be avoided as it may damage the seals. The FPCCEAN2D24A fits into a T-13A cavity and has a capacity of 10 gpm (40 L/min), making it suitable for various hydraulic applications requiring precise flow control solutions.
This valve is a normally-closed, electro-proportional throttle. The valve is spring biased closed. Energizing the coil generates an opening force on the spool proportional to the command current and this force is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The valve exhibits a large degree of self-compensation in the 1 to 2 direction and will provide proportional flow control in the 2 to 1 direction with the addition of an external compensator. Full reverse flow (2 to 1) with 100% command in the 2 to 1 direction is possible without a compensator under all conditions.
- Available in either a normally open or normally closed configuration with three different capacity ranges.
- Capable of operating with pressures up to 5000 psi.
- Low leakage levels in the closed position.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-13A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 6 in³/min.@3000 psi100 cc/min.@210 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-413-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ