SUN HYDRAULICS
FPCCEAV724
$286.22 USD
- SUN HYDRAULICS
- Material:FPCCEAV724
- Model:FPCC-EAV@724
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPCCEAV724 (FPCCEAV724) is a normally closed, electro-proportional throttle valve. This valve is spring-biased to remain closed until the coil is energized, creating an opening force on the spool that correlates with the command current. This action results in a metering orifice whose size adjusts proportionally to the current applied. The FPCCEAV724 valve offers significant self-compensation in the 1 to 2 flow direction and can deliver proportional flow control in the 2 to 1 direction when paired with an external compensator. It allows full reverse flow from 2 to 1 with a full command without needing a compensator under all conditions. Available configurations include normally open or normally closed options with three capacity ranges, making it adaptable for various applications. The valve operates efficiently at pressures up to 5000 psi and features low leakage levels when closed. Its coils are interchangeable with other Sun solenoid-operated valves and can be mounted in either direction on the tube. For enhanced performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. Manual override options include temporary actuation controls such as D, E, L, and T assemblies, which have a mechanical life expectancy of about 7,000 cycles. The momentary-twist override option E allows manual shifting of the valve by twisting it clockwise by 90 degrees. This cartridge uses EPDM seals suitable for systems utilizing phosphate ester fluids but should not be exposed to petroleum-based fluids as they may cause damage. It incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations in cavity-cartridge applications. With a capacity of up to 10 gpm (40 L/min), this model ensures reliable performance across diverse operational demands.
The Sun Hydraulics FPCCEAV724 (FPCCEAV724) is a normally closed, electro-proportional throttle valve. This valve is spring-biased to remain closed until the coil is energized, creating an opening force on the spool that correlates with the command current. This action results in a metering orifice whose size adjusts proportionally to the current applied. The FPCCEAV724 valve offers significant self-compensation in the 1 to 2 flow direction and can deliver proportional flow control in the 2 to 1 direction when paired with an external compensator. It allows full reverse flow from 2 to 1 with a full command without needing a compensator under all conditions. Available configurations include normally open or normally closed options with three capacity ranges, making it adaptable for various applications. The valve operates efficiently at pressures up to 5000 psi and features low leakage levels when closed. Its coils are interchangeable with other Sun solenoid-operated valves and can be mounted in either direction on the tube. For enhanced performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. Manual override options include temporary actuation controls such as D, E, L, and T assemblies, which have a mechanical life expectancy of about 7,000 cycles. The momentary-twist override option E allows manual shifting of the valve by twisting it clockwise by 90 degrees. This cartridge uses EPDM seals suitable for systems utilizing phosphate ester fluids but should not be exposed to petroleum-based fluids as they may cause damage. It incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations in cavity-cartridge applications. With a capacity of up to 10 gpm (40 L/min), this model ensures reliable performance across diverse operational demands.
This valve is a normally-closed, electro-proportional throttle. The valve is spring biased closed. Energizing the coil generates an opening force on the spool proportional to the command current and this force is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The valve exhibits a large degree of self-compensation in the 1 to 2 direction and will provide proportional flow control in the 2 to 1 direction with the addition of an external compensator. Full reverse flow (2 to 1) with 100% command in the 2 to 1 direction is possible without a compensator under all conditions.
- Available in either a normally open or normally closed configuration with three different capacity ranges.
- Capable of operating with pressures up to 5000 psi.
- Low leakage levels in the closed position.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-13A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 6 in³/min.@3000 psi100 cc/min.@210 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-413-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |