SUN HYDRAULICS
FPCCTAV512
$259.42 USD
- SUN HYDRAULICS
- Material:FPCCTAV512
- Model:FPCC-TAV@512
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPCCTAV512 (FPCCTAV512) is a normally closed, electro-proportional throttle valve designed for precise flow control in hydraulic systems. This valve is spring-biased to remain closed and opens proportionally to the command current applied, balancing the opening force with spring and flow forces to create a metering orifice. The FPCCTAV512 offers significant self-compensation in the 1 to 2 direction, allowing for proportional flow control in the reverse direction with an external compensator. It supports full reverse flow without a compensator under all conditions when fully energized. Available configurations include normally open or closed options with three capacity ranges, making it versatile for various applications. The valve operates efficiently at pressures up to 5000 psi and maintains low leakage levels when closed. The FPCCTAV512 features interchangeable coils compatible with other Sun solenoid-operated valves, offering ease of installation as they can be mounted in either direction. For enhanced performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. Manual override options include several configurations such as temporary actuation detents and a momentary-twist override mechanism. EPDM seal variants are available for systems using phosphate ester fluids, while exposure to petroleum-based fluids should be avoided. The cartridge employs Sun's floating style construction to reduce internal binding risks due to installation torque or machining variations. With a capacity of 10 gpm (40 L/min) and minimal leakage at high pressures, this model ensures reliable operation in demanding environments. The FPCCTAV512 fits into cavity T-13A and requires specific installation torque values for optimal functioning.
The Sun Hydraulics FPCCTAV512 (FPCCTAV512) is a normally closed, electro-proportional throttle valve designed for precise flow control in hydraulic systems. This valve is spring-biased to remain closed and opens proportionally to the command current applied, balancing the opening force with spring and flow forces to create a metering orifice. The FPCCTAV512 offers significant self-compensation in the 1 to 2 direction, allowing for proportional flow control in the reverse direction with an external compensator. It supports full reverse flow without a compensator under all conditions when fully energized. Available configurations include normally open or closed options with three capacity ranges, making it versatile for various applications. The valve operates efficiently at pressures up to 5000 psi and maintains low leakage levels when closed. The FPCCTAV512 features interchangeable coils compatible with other Sun solenoid-operated valves, offering ease of installation as they can be mounted in either direction. For enhanced performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. Manual override options include several configurations such as temporary actuation detents and a momentary-twist override mechanism. EPDM seal variants are available for systems using phosphate ester fluids, while exposure to petroleum-based fluids should be avoided. The cartridge employs Sun's floating style construction to reduce internal binding risks due to installation torque or machining variations. With a capacity of 10 gpm (40 L/min) and minimal leakage at high pressures, this model ensures reliable operation in demanding environments. The FPCCTAV512 fits into cavity T-13A and requires specific installation torque values for optimal functioning.
This valve is a normally-closed, electro-proportional throttle. The valve is spring biased closed. Energizing the coil generates an opening force on the spool proportional to the command current and this force is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The valve exhibits a large degree of self-compensation in the 1 to 2 direction and will provide proportional flow control in the 2 to 1 direction with the addition of an external compensator. Full reverse flow (2 to 1) with 100% command in the 2 to 1 direction is possible without a compensator under all conditions.
- Available in either a normally open or normally closed configuration with three different capacity ranges.
- Capable of operating with pressures up to 5000 psi.
- Low leakage levels in the closed position.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-13A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 6 in³/min.@3000 psi100 cc/min.@210 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-413-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ