You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
FPCCXAN812N


$217.82 USD
  • SUN HYDRAULICS
  • Material:FPCCXAN812N
  • Model:FPCC-XAN@812N
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPCCXAN812N (FPCCXAN812N) is a normally closed, electro-proportional throttle valve designed to provide precise flow control in hydraulic systems. This valve operates by balancing the opening force generated by an energized coil against spring and flow forces, creating a metering orifice proportional to the command current. It offers significant self-compensation in the 1 to 2 direction and can achieve proportional flow control in the 2 to 1 direction with an external compensator. The valve allows full reverse flow from 2 to 1 without a compensator under all conditions when fully commanded. Available configurations include normally open or closed setups, with three capacity ranges, and it can handle pressures up to 5000 psi while maintaining low leakage levels when closed. The interchangeable coils can be mounted in either direction on the solenoid tube, and various manual override options are available, including a momentary twist override for temporary actuation. For optimal performance, the use of an amplifier with current sensing and adjustable dither (between 100-250 Hz) is recommended. The cartridge features Sun's floating style construction to minimize internal binding due to installation torque or machining variations. It fits into cavity T-13A, with a series capacity of 10 gpm (40 L/min). The valve is lightweight at approximately 1.10 lb (0.50 kg) including the coil and requires specific installation torque for proper function. Seal kits are available for maintenance needs, ensuring compatibility with different fluid types like phosphate ester fluids using EPDM seals while avoiding petroleum-based fluids that could damage these seals.

This valve is a normally-closed, electro-proportional throttle. The valve is spring biased closed. Energizing the coil generates an opening force on the spool proportional to the command current and this force is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The valve exhibits a large degree of self-compensation in the 1 to 2 direction and will provide proportional flow control in the 2 to 1 direction with the addition of an external compensator. Full reverse flow (2 to 1) with 100% command in the 2 to 1 direction is possible without a compensator under all conditions.

  • Available in either a normally open or normally closed configuration with three different capacity ranges.
  • Capable of operating with pressures up to 5000 psi.
  • Low leakage levels in the closed position.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • This cartridge has several manual override choices, including no manual override. See Option Configuration.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
  • Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-13A
Series 1
Capacity 10 gpm40 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 6 in³/min.@3000 psi100 cc/min.@210 bar
Manual Override Force Requirement 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1
Manual Override Stroke .10 in.2,5 mm
Solenoid Tube Diameter .75 in.19 mm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil) 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-413-006
Seal and nut kit - Coil Viton: 990-770-006Viton: 990-770-006

Show FAQ