***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPCCXBE914 (FPCCXBE914) is a normally-closed, electroproportional throttle valve designed for precise flow control in hydraulic systems. This valve operates by using an electromagnetic coil to generate an opening force on the spool that is proportional to the command current, countered by spring and flow forces. This interaction creates a metering orifice whose effective size adjusts according to the current, allowing for fine-tuned flow regulation. The FPCCXBE914 offers significant self-compensation in the 1 to 2 direction and can achieve proportional flow control in the reverse direction with an external compensator. Without a compensator, it can still provide full reverse flow under all conditions when commanded at maximum capacity. Available configurations include normally open or closed setups with three capacity ranges, capable of handling pressures up to 5000 psi. It features low leakage levels when closed and interchangeable coils compatible with other Sun solenoid-operated valves. Installation flexibility is enhanced by manual override options and compatibility with cartridges equipped with EPDM seals for phosphate ester fluid systems. The Sun floating style construction minimizes potential binding due to installation torque variations. For optimal performance, it's recommended to use this valve with an amplifier featuring current sensing and adjustable dither between 100-250 Hz. The FPCCXBE914's manual override options include temporary actuation mechanisms and momentary-twist overrides for operational convenience. This cartridge fits into T13A cavities, has a series 1 capacity of 10 gpm (40 L/min), and maintains low leakage rates of up to 100 cc/min at specified conditions. With its robust design and versatile capabilities, this valve is suitable for applications requiring precise hydraulic control under varying operational demands.
The Sun Hydraulics FPCCXBE914 (FPCCXBE914) is a normally-closed, electroproportional throttle valve designed for precise flow control in hydraulic systems. This valve operates by using an electromagnetic coil to generate an opening force on the spool that is proportional to the command current, countered by spring and flow forces. This interaction creates a metering orifice whose effective size adjusts according to the current, allowing for fine-tuned flow regulation. The FPCCXBE914 offers significant self-compensation in the 1 to 2 direction and can achieve proportional flow control in the reverse direction with an external compensator. Without a compensator, it can still provide full reverse flow under all conditions when commanded at maximum capacity. Available configurations include normally open or closed setups with three capacity ranges, capable of handling pressures up to 5000 psi. It features low leakage levels when closed and interchangeable coils compatible with other Sun solenoid-operated valves. Installation flexibility is enhanced by manual override options and compatibility with cartridges equipped with EPDM seals for phosphate ester fluid systems. The Sun floating style construction minimizes potential binding due to installation torque variations. For optimal performance, it's recommended to use this valve with an amplifier featuring current sensing and adjustable dither between 100-250 Hz. The FPCCXBE914's manual override options include temporary actuation mechanisms and momentary-twist overrides for operational convenience. This cartridge fits into T13A cavities, has a series 1 capacity of 10 gpm (40 L/min), and maintains low leakage rates of up to 100 cc/min at specified conditions. With its robust design and versatile capabilities, this valve is suitable for applications requiring precise hydraulic control under varying operational demands.
This valve is a normally-closed, electro-proportional throttle. The valve is spring biased closed. Energizing the coil generates an opening force on the spool proportional to the command current and this force is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The valve exhibits a large degree of self-compensation in the 1 to 2 direction and will provide proportional flow control in the 2 to 1 direction with the addition of an external compensator. Full reverse flow (2 to 1) with 100% command in the 2 to 1 direction is possible without a compensator under all conditions.
- Available in either a normally open or normally closed configuration with three different capacity ranges.
- Capable of operating with pressures up to 5000 psi.
- Low leakage levels in the closed position.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-13A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 6 in³/min.@3000 psi100 cc/min.@210 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-413-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |