You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
FPCHDCV224


$235.00 USD
  • SUN HYDRAULICS
  • Material:FPCHDCV224
  • Model:FPCH-DCV@224
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPCHDCV224 (FPCHDCV224) is a versatile, normally-open electroproportional throttle valve designed for precise flow control in hydraulic systems. This valve operates by balancing an electromagnetic force against a spring and flow forces, creating a metering orifice whose size adjusts proportionally to the input current. It is capable of handling pressures up to 5000 psi and offers low leakage levels when closed. The FPCHDCV224 can be configured as either normally open or normally closed and is available in three different capacity ranges. Notably, it allows for full reverse flow from port 2 to port 1 without command in the absence of an external compensator. The valve's design includes interchangeable coils compatible with other Sun solenoid-operated valves, providing flexibility in installation. Various manual override options are available, including a momentary-twist option that requires a simple 90-degree twist to actuate the valve manually. For optimal performance, it is recommended to use this valve with an amplifier featuring current sensing and adjustable dither between 100-250 Hz. The mechanical life expectancy of manual control assemblies varies by type but averages around 7,000 cycles for certain models. Constructed using Sun's floating style design, this cartridge minimizes risks of internal part binding due to installation torque or machining variations. The FPCHDCV224 fits into cavity T-13A and belongs to series 1 with a capacity of up to 7 gpm (28 L/min). Its compact design features a solenoid tube diameter of .75 inches (19 mm) and requires an installation torque between 30-35 lbf ft (41-47 Nm). Seal kits are available with Viton material for enhanced durability under demanding conditions.

This valve is a normally-open, electro-proportional throttle. The valve is spring biased open. Energizing the coil generates an closing force on the spool proportional to the command current and this force is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The valve exhibits a large degree of self-compensation in the 1 to 2 direction and will provide proportional flow control in the 2 to 1 direction with the addition of an external compensator. Full reverse flow (2 to 1) with no command in the 2 to 1 direction is possible without a compensator under all conditions.

  • Available in either a normally open or normally closed configuration with three different capacity ranges.
  • Capable of operating with pressures up to 5000 psi.
  • Low leakage levels in the closed position.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • This cartridge has several manual override choices, including no manual override. See Option Configuration.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-13A
Series 1
Capacity 7 gpm28 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 6 in³/min.@3000 psi100 cc/min.@210 bar
Manual Override Force Requirement 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1
Manual Override Stroke .10 in.2,5 mm
Solenoid Tube Diameter .75 in.19 mm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil) 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-413-006
Seal and nut kit - Coil Viton: 990-770-006Viton: 990-770-006

Show FAQ