You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
FPCHDCV2C12V


$529.36 USD
  • SUN HYDRAULICS
  • Material:FPCHDCV2C12V
  • Model:FPCH-DCV@2C12V
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPCHDCV2C12V (FPCHDCV2C12V) is a versatile electro-proportional throttle valve designed for precise flow control in hydraulic systems. This normally-open valve is spring-biased to remain open and can be closed proportionally by energizing the coil, which creates a force on the spool that is countered by spring and flow forces. This balance of forces results in a metering orifice whose size is directly proportional to the input current. The valve excels in self-compensation from port 1 to port 2 and provides proportional flow control in the opposite direction with an external compensator. It allows full reverse flow from port 2 to port 1 without command under all conditions, eliminating the need for a compensator. The valve offers flexibility with configurations available as normally open or closed, along with three capacity ranges. It operates efficiently under pressures up to 5000 psi while maintaining low leakage levels when closed. The coils are interchangeable with other Sun solenoid-operated valves, enhancing compatibility within systems. Manual override options are diverse, including choices without an override feature, ensuring adaptability for various applications. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. Incorporating Sun's floating style construction minimizes potential binding issues due to installation torque or machining variations. The FPCHDCV2C12V fits into T-13A cavities and belongs to Series 1 with a capacity of 7 gpm (28 L/min). Additional specifications include a maximum leakage rate of 6 in\u00b3/min at 3000 psi (100 cc/min at 210 bar), manual override force requirement of 5 lbs/1000 psi (33 N/100 bar), and a solenoid tube diameter of .75 inches (19 mm). The valve's installation torque ranges from 30-35 lbf-ft (41-47 Nm), and it weighs approximately 1.10 lb (0.50 kg) when equipped with a coil.

This valve is a normally-open, electro-proportional throttle. The valve is spring biased open. Energizing the coil generates an closing force on the spool proportional to the command current and this force is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The valve exhibits a large degree of self-compensation in the 1 to 2 direction and will provide proportional flow control in the 2 to 1 direction with the addition of an external compensator. Full reverse flow (2 to 1) with no command in the 2 to 1 direction is possible without a compensator under all conditions.

  • Available in either a normally open or normally closed configuration with three different capacity ranges.
  • Capable of operating with pressures up to 5000 psi.
  • Low leakage levels in the closed position.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • This cartridge has several manual override choices, including no manual override. See Option Configuration.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-13A
Series 1
Capacity 7 gpm28 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 6 in³/min.@3000 psi100 cc/min.@210 bar
Manual Override Force Requirement 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1
Manual Override Stroke .10 in.2,5 mm
Solenoid Tube Diameter .75 in.19 mm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil) 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-413-006
Seal and nut kit - Coil Viton: 990-770-006Viton: 990-770-006

Show FAQ