You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
FPCHLBV214N


$245.82 USD
  • SUN HYDRAULICS
  • Material:FPCHLBV214N
  • Model:FPCH-LBV@214N
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPCHLBV214N (Material Number: FPCHLBV214N) is a normally-open, electroproportional throttle valve designed for precise flow control in hydraulic systems. This valve is spring-biased open, and the application of current to the coil generates a closing force on the spool that is proportional to the command current. This force is counterbalanced by the spring and flow forces, creating a metering orifice whose effective size adjusts with the current. The FPCHLBV214N provides substantial self-compensation in one direction and allows for proportional flow control in the reverse direction when used with an external compensator. Notably, full reverse flow without command is achievable under all conditions without a compensator. This model can operate at pressures up to 5000 psi and features low leakage levels when closed. It is compatible with interchangeable coils from Sun's other solenoid-operated valves, allowing flexibility in installation orientation. The valve offers several manual override options, including configurations without manual override, and requires an amplifier with adjustable dither for optimal performance. The manual override mechanism has a mechanical life expectancy of approximately 7,000 cycles. The FPCHLBV214N incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. It fits into a T-13A cavity and belongs to Series 1 with a capacity of 7 gpm (28 L/min). The valve's design ensures reliable operation across various applications requiring precise hydraulic control, making it suitable for systems where consistent performance under high pressure is essential.

This valve is a normally-open, electro-proportional throttle. The valve is spring biased open. Energizing the coil generates an closing force on the spool proportional to the command current and this force is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The valve exhibits a large degree of self-compensation in the 1 to 2 direction and will provide proportional flow control in the 2 to 1 direction with the addition of an external compensator. Full reverse flow (2 to 1) with no command in the 2 to 1 direction is possible without a compensator under all conditions.

  • Available in either a normally open or normally closed configuration with three different capacity ranges.
  • Capable of operating with pressures up to 5000 psi.
  • Low leakage levels in the closed position.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • This cartridge has several manual override choices, including no manual override. See Option Configuration.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-13A
Series 1
Capacity 7 gpm28 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 6 in³/min.@3000 psi100 cc/min.@210 bar
Manual Override Force Requirement 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1
Manual Override Stroke .10 in.2,5 mm
Solenoid Tube Diameter .75 in.19 mm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil) 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-413-006
Seal and nut kit - Coil Viton: 990-770-006Viton: 990-770-006

Show FAQ