SUN HYDRAULICS
FPCHMCN2C12V
$502.06 USD
- SUN HYDRAULICS
- Material:FPCHMCN2C12V
- Model:FPCH-MCN@2C12V
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPCHMCN2C12V (FPCHMCN2C12V) is a normally-open, electro-proportional throttle valve designed for precise flow control in hydraulic systems. This valve operates with pressures up to 5000 psi and features low leakage levels when closed. It is spring-biased open, and the coil can be energized to generate a closing force on the spool proportional to the command current. This force is countered by the spring and flow forces, creating a metering orifice whose effective size varies with the current. The valve offers self-compensation in the 1 to 2 direction and allows for proportional flow control in the 2 to 1 direction with an external compensator. Full reverse flow from port 2 to port 1 without command is possible without a compensator. Available in both normally open or closed configurations, it supports three different capacity ranges, making it versatile for various applications. The valve incorporates Sun's floating style construction, minimizing internal part binding due to excessive installation torque or machining variations. It also offers interchangeable coils with other full-flow solenoid-operated valves from Sun Hydraulics, allowing flexible installation options. For optimal performance, using an amplifier with current sensing and adjustable dither between 100-250 Hz is recommended. The model includes several manual override options, including momentary-twist override (option E), which allows shifting by twisting the manual override clockwise by 90 degrees. The detent mechanism in models equipped with D or L control is intended for temporary actuation only, with manual control assemblies having a mechanical life expectancy of approximately 7,000 cycles. The valve fits into cavity T-13A and has a capacity of up to 7 gpm (28 L/min). It requires specific installation torque settings and comes with Viton seal kits available for both cartridge and coil components.
The Sun Hydraulics FPCHMCN2C12V (FPCHMCN2C12V) is a normally-open, electro-proportional throttle valve designed for precise flow control in hydraulic systems. This valve operates with pressures up to 5000 psi and features low leakage levels when closed. It is spring-biased open, and the coil can be energized to generate a closing force on the spool proportional to the command current. This force is countered by the spring and flow forces, creating a metering orifice whose effective size varies with the current. The valve offers self-compensation in the 1 to 2 direction and allows for proportional flow control in the 2 to 1 direction with an external compensator. Full reverse flow from port 2 to port 1 without command is possible without a compensator. Available in both normally open or closed configurations, it supports three different capacity ranges, making it versatile for various applications. The valve incorporates Sun's floating style construction, minimizing internal part binding due to excessive installation torque or machining variations. It also offers interchangeable coils with other full-flow solenoid-operated valves from Sun Hydraulics, allowing flexible installation options. For optimal performance, using an amplifier with current sensing and adjustable dither between 100-250 Hz is recommended. The model includes several manual override options, including momentary-twist override (option E), which allows shifting by twisting the manual override clockwise by 90 degrees. The detent mechanism in models equipped with D or L control is intended for temporary actuation only, with manual control assemblies having a mechanical life expectancy of approximately 7,000 cycles. The valve fits into cavity T-13A and has a capacity of up to 7 gpm (28 L/min). It requires specific installation torque settings and comes with Viton seal kits available for both cartridge and coil components.
This valve is a normally-open, electro-proportional throttle. The valve is spring biased open. Energizing the coil generates an closing force on the spool proportional to the command current and this force is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The valve exhibits a large degree of self-compensation in the 1 to 2 direction and will provide proportional flow control in the 2 to 1 direction with the addition of an external compensator. Full reverse flow (2 to 1) with no command in the 2 to 1 direction is possible without a compensator under all conditions.
- Available in either a normally open or normally closed configuration with three different capacity ranges.
- Capable of operating with pressures up to 5000 psi.
- Low leakage levels in the closed position.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-13A |
| Series | 1 |
| Capacity | 7 gpm28 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 6 in³/min.@3000 psi100 cc/min.@210 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-413-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ