***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKMEV214N (FPHKMEV214N) is a pilot-operated, normally closed, electroproportional throttle valve with a reverse free flow check feature. This valve operates by energizing the coil to generate an opening force on the pilot stage, which in turn vents the main stage poppet for proportional opening. It is designed for metered flow from port 1 to port 2, while allowing reverse free flow from port 2 to port 1. It can handle pressures up to 5000 psi and has a capacity of 60 gpm (240 L/min). The valve incorporates Sun\u2019s floating style construction to minimize internal part binding due to excessive installation torque or machining variations. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve offers several manual override options, including a momentary twist override that allows manual shifting by twisting clockwise by 90 degrees. The interchangeable coils can be mounted in either direction on the tube, enhancing flexibility and compatibility with other Sun solenoid-operated valves. The cartridge requires a cavity size of T16A and falls under series 3 specifications. With a maximum leakage rate of 10 drops/min at 5000 psi and various seal kit options like Viton: 990016006 for cartridges, this model ensures reliable operation under demanding conditions. The installation torque ranges between 150-160 lbf ft (203-217 Nm), ensuring secure fitting during setup.
The Sun Hydraulics FPHKMEV214N (FPHKMEV214N) is a pilot-operated, normally closed, electroproportional throttle valve with a reverse free flow check feature. This valve operates by energizing the coil to generate an opening force on the pilot stage, which in turn vents the main stage poppet for proportional opening. It is designed for metered flow from port 1 to port 2, while allowing reverse free flow from port 2 to port 1. It can handle pressures up to 5000 psi and has a capacity of 60 gpm (240 L/min). The valve incorporates Sun\u2019s floating style construction to minimize internal part binding due to excessive installation torque or machining variations. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve offers several manual override options, including a momentary twist override that allows manual shifting by twisting clockwise by 90 degrees. The interchangeable coils can be mounted in either direction on the tube, enhancing flexibility and compatibility with other Sun solenoid-operated valves. The cartridge requires a cavity size of T16A and falls under series 3 specifications. With a maximum leakage rate of 10 drops/min at 5000 psi and various seal kit options like Viton: 990016006 for cartridges, this model ensures reliable operation under demanding conditions. The installation torque ranges between 150-160 lbf ft (203-217 Nm), ensuring secure fitting during setup.
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-16A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Recommended dither frequency | 100 Hz100 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Deadband, nominal (as a percentage of input) | 25%25% |
| Manual Override Stroke | .06 in.1,50 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Model Weight (with coil) | 2.00 lb2.00 lb |
| Seal kit - Cartridge | Viton: 990-016-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ