SUN HYDRAULICS
FPHKXCV2F12V
$590.91 USD
- SUN HYDRAULICS
- Material:FPHKXCV2F12V
- Model:FPHK-XCV@2F12V
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKXCV2F12V (FPHKXCV2F12V) is a pilot-operated, normally closed, electroproportional throttle valve with a reverse free flow check feature. This valve is designed to handle pressures up to 5000 psi and allows for metered flow from port 1 to port 2, with reverse free flow from port 2 to port 1. The coil, which can be mounted in either direction, is interchangeable with Sun's other full-flow solenoid-operated valves. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve also offers several manual override options, including a momentary-twist override that allows the operator to shift the valve by twisting the manual override clockwise by 90 degrees. The floating style construction of this cartridge minimizes potential binding issues due to excessive installation torque or machining variations. It fits into a T16A cavity and belongs to Series 3, offering a capacity of up to 60 gpm (240 L/min). The valve requires a manual override force of approximately 5 lbs at 1000 psi on Port 1 and has a nominal deadband as a percentage of input at around 25%. It features a solenoid tube diameter of .75 inches (19 mm) and has an installation torque range of 150-160 lbf ft (203-217 Nm). With various seal kit options available, such as Viton: 990016006 for cartridges and Viton: 990770006 for coils, this model weighs about 1.50 lb without the coil and approximately 2.00 lb with the coil included.
The Sun Hydraulics FPHKXCV2F12V (FPHKXCV2F12V) is a pilot-operated, normally closed, electroproportional throttle valve with a reverse free flow check feature. This valve is designed to handle pressures up to 5000 psi and allows for metered flow from port 1 to port 2, with reverse free flow from port 2 to port 1. The coil, which can be mounted in either direction, is interchangeable with Sun's other full-flow solenoid-operated valves. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve also offers several manual override options, including a momentary-twist override that allows the operator to shift the valve by twisting the manual override clockwise by 90 degrees. The floating style construction of this cartridge minimizes potential binding issues due to excessive installation torque or machining variations. It fits into a T16A cavity and belongs to Series 3, offering a capacity of up to 60 gpm (240 L/min). The valve requires a manual override force of approximately 5 lbs at 1000 psi on Port 1 and has a nominal deadband as a percentage of input at around 25%. It features a solenoid tube diameter of .75 inches (19 mm) and has an installation torque range of 150-160 lbf ft (203-217 Nm). With various seal kit options available, such as Viton: 990016006 for cartridges and Viton: 990770006 for coils, this model weighs about 1.50 lb without the coil and approximately 2.00 lb with the coil included.
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-16A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Recommended dither frequency | 100 Hz100 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Deadband, nominal (as a percentage of input) | 25%25% |
| Manual Override Stroke | .06 in.1,50 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Model Weight (with coil) | 2.00 lb2.00 lb |
| Seal kit - Cartridge | Viton: 990-016-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |