SUN HYDRAULICS
FPHKXEN924N
$364.16 USD
- SUN HYDRAULICS
- Material:FPHKXEN924N
- Model:FPHK-XEN@924N
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKXEN924N (FPHKXEN924N) is a pilot-operated, normally closed, electroproportional throttle valve featuring a reverse free flow check. When the coil is energized, it generates an opening force on the pilot stage, venting the main stage poppet to open proportionally. This allows metered flow from port 1 to port 2 and reverse free flow from port 2 to port 1. The valve can operate under pressures up to 5000 psi and has a capacity of handling up to 60 gpm (240 L/min). It incorporates Sun's floating style construction, which minimizes internal part binding due to excessive installation torque or machining variations. The cartridge fits into a T16A cavity and offers several manual override options, including a momentary twist override that shifts the valve by twisting the manual override clockwise by 90 degrees. For optimal performance, using an amplifier with current sensing and adjustable dither between 100-250 Hz is recommended. The solenoid tube diameter is .75 inches (19 mm), while the valve hex size is 1\u00bc inches (31.8 mm), with an installation torque requirement of 150-160 lbf ft (203-217 Nm). Maximum leakage at 110 SUS (24 cSt) is rated at 10 drops/min at 5000 psi (0.7 cc/min at 350 bar). The product weighs approximately 1.50 lb without coil and includes Viton seal kits for both cartridge and coil applications.
The Sun Hydraulics FPHKXEN924N (FPHKXEN924N) is a pilot-operated, normally closed, electroproportional throttle valve featuring a reverse free flow check. When the coil is energized, it generates an opening force on the pilot stage, venting the main stage poppet to open proportionally. This allows metered flow from port 1 to port 2 and reverse free flow from port 2 to port 1. The valve can operate under pressures up to 5000 psi and has a capacity of handling up to 60 gpm (240 L/min). It incorporates Sun's floating style construction, which minimizes internal part binding due to excessive installation torque or machining variations. The cartridge fits into a T16A cavity and offers several manual override options, including a momentary twist override that shifts the valve by twisting the manual override clockwise by 90 degrees. For optimal performance, using an amplifier with current sensing and adjustable dither between 100-250 Hz is recommended. The solenoid tube diameter is .75 inches (19 mm), while the valve hex size is 1\u00bc inches (31.8 mm), with an installation torque requirement of 150-160 lbf ft (203-217 Nm). Maximum leakage at 110 SUS (24 cSt) is rated at 10 drops/min at 5000 psi (0.7 cc/min at 350 bar). The product weighs approximately 1.50 lb without coil and includes Viton seal kits for both cartridge and coil applications.
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-16A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Recommended dither frequency | 100 Hz100 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Deadband, nominal (as a percentage of input) | 25%25% |
| Manual Override Stroke | .06 in.1,50 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Model Weight (with coil) | 2.00 lb2.00 lb |
| Seal kit - Cartridge | Viton: 990-016-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ