SUN HYDRAULICS
FPHKXEV4F24V
$590.82 USD
- SUN HYDRAULICS
- Material:FPHKXEV4F24V
- Model:FPHK-XEV@4F24V
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKXEV4F24V (FPHKXEV4F24V) is a pilot-operated, normally closed, electroproportional throttle valve featuring reverse free flow check capabilities. When the coil is energized, it generates an opening force on the pilot stage, which vents the main stage poppet to open proportionally. This allows metered flow from port 1 to port 2 while permitting reverse free flow from port 2 to port 1. The valve can operate under pressures up to 5000 psi and is compatible with interchangeable coils used in other Sun solenoid-operated valves. It can be mounted on the tube in either direction for versatile installation. The cartridge offers several manual override options, including a momentary twist override (Option E), which allows manual shifting of the valve by twisting clockwise 90 degrees. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve incorporates Sun's floating style construction to minimize potential binding of internal parts due to excessive installation torque or machining variations. Key specifications include a cavity size of T16A, series number 3, and a capacity of 60 gpm (240 L/min). The valve has a recommended dither frequency of 100 Hz and maximum leakage at specific conditions is limited to 10 drops/min at 5000 psi (0.7 cc/min at 350 bar). Manual override requires a force of approximately 5 lbs per 1000 psi at Port 1 (33 N/100 bar). The solenoid tube diameter is .75 inches (19 mm), with a hex size of 1-1/4 inches (31.8 mm) and installation torque ranging from 150-160 lbf-ft (203-217 Nm). The model weight without coil is approximately 1.50 lb (0.70 kg), and with coil, it weighs around 2.00 lb. Seal kits are available in Viton material for both cartridge and coil components.
The Sun Hydraulics FPHKXEV4F24V (FPHKXEV4F24V) is a pilot-operated, normally closed, electroproportional throttle valve featuring reverse free flow check capabilities. When the coil is energized, it generates an opening force on the pilot stage, which vents the main stage poppet to open proportionally. This allows metered flow from port 1 to port 2 while permitting reverse free flow from port 2 to port 1. The valve can operate under pressures up to 5000 psi and is compatible with interchangeable coils used in other Sun solenoid-operated valves. It can be mounted on the tube in either direction for versatile installation. The cartridge offers several manual override options, including a momentary twist override (Option E), which allows manual shifting of the valve by twisting clockwise 90 degrees. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve incorporates Sun's floating style construction to minimize potential binding of internal parts due to excessive installation torque or machining variations. Key specifications include a cavity size of T16A, series number 3, and a capacity of 60 gpm (240 L/min). The valve has a recommended dither frequency of 100 Hz and maximum leakage at specific conditions is limited to 10 drops/min at 5000 psi (0.7 cc/min at 350 bar). Manual override requires a force of approximately 5 lbs per 1000 psi at Port 1 (33 N/100 bar). The solenoid tube diameter is .75 inches (19 mm), with a hex size of 1-1/4 inches (31.8 mm) and installation torque ranging from 150-160 lbf-ft (203-217 Nm). The model weight without coil is approximately 1.50 lb (0.70 kg), and with coil, it weighs around 2.00 lb. Seal kits are available in Viton material for both cartridge and coil components.
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-16A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Recommended dither frequency | 100 Hz100 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Deadband, nominal (as a percentage of input) | 25%25% |
| Manual Override Stroke | .06 in.1,50 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Model Weight (with coil) | 2.00 lb2.00 lb |
| Seal kit - Cartridge | Viton: 990-016-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ