SUN HYDRAULICS
FRDALAV
$97.00 USD
- SUN HYDRAULICS
- Material:FRDALAV
- Model:FRDA-LAV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FRDALAV (Material Number: FRDALAV) is a bypass-restrictive, fixed-orifice, priority flow control valve designed to manage input flow effectively by prioritizing the flow at port 3 while bypassing any excess through port 2. This model is ideal for applications requiring precise flow management where the priority flow must remain constant despite variations in input flow. The valve can handle a maximum pressure of 3000 psi (210 bar) at port 3 and supports both priority and bypass flows up to the system's operating pressure. The construction includes a sharp-edged orifice that minimizes flow variation due to changes in viscosity, and a tuneable adjustment feature allows for up to 25% variation from the nominal factory preset flow using an adjustment screw with three turns. The FRDALAV incorporates Sun's floating style construction, which reduces the risk of internal parts binding due to excessive installation torque or machining variations. It fits into a T-2A cavity and is capable of handling up to 12 gpm (45 L/min) with a maximum input flow of 30 gpm (120 L/min). The valve is compact with dimensions suitable for various installation needs; it has a hex size of 1-1/8 inches (28.6 mm) and requires an installation torque between 45-50 lbf ft (61-68 Nm). For secure adjustments, it includes an internal hex size of 5/32 inches (4 mm) for the adjustment screw and a locknut hex size of 9/16 inches (15 mm) with torque specifications of 80-90 lbf in (9-10 Nm). This model weighs approximately .40 lb (.20 kg) and uses Viton seals with cartridge seal kit number 990202006 available for maintenance purposes.
The Sun Hydraulics FRDALAV (Material Number: FRDALAV) is a bypass-restrictive, fixed-orifice, priority flow control valve designed to manage input flow effectively by prioritizing the flow at port 3 while bypassing any excess through port 2. This model is ideal for applications requiring precise flow management where the priority flow must remain constant despite variations in input flow. The valve can handle a maximum pressure of 3000 psi (210 bar) at port 3 and supports both priority and bypass flows up to the system's operating pressure. The construction includes a sharp-edged orifice that minimizes flow variation due to changes in viscosity, and a tuneable adjustment feature allows for up to 25% variation from the nominal factory preset flow using an adjustment screw with three turns. The FRDALAV incorporates Sun's floating style construction, which reduces the risk of internal parts binding due to excessive installation torque or machining variations. It fits into a T-2A cavity and is capable of handling up to 12 gpm (45 L/min) with a maximum input flow of 30 gpm (120 L/min). The valve is compact with dimensions suitable for various installation needs; it has a hex size of 1-1/8 inches (28.6 mm) and requires an installation torque between 45-50 lbf ft (61-68 Nm). For secure adjustments, it includes an internal hex size of 5/32 inches (4 mm) for the adjustment screw and a locknut hex size of 9/16 inches (15 mm) with torque specifications of 80-90 lbf in (9-10 Nm). This model weighs approximately .40 lb (.20 kg) and uses Viton seals with cartridge seal kit number 990202006 available for maintenance purposes.
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow may be used in a secondary circuit.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Both priority and bypass flow are usable up to the system operating pressure.
- Priority remains relatively constant regardless of variation in input flow.
- Bypass flow is not available until priority flow requirements are satisfied.
- Pressure at the bypass port (port 2) may exceed pressure at the priority port (port 3).
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- A tuneable adjustment control option provides up to +/- 25% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw. Screw in (CW) to increase flow.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 12 gpm45 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Input Flow | 30 gpm120 L/min. |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ