SUN HYDRAULICS
FRDALBN
$89.05 USD
- SUN HYDRAULICS
- Material:FRDALBN
- Model:FRDA-LBN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FRDALBN (Material Number: FRDALBN) is a bypass restrictive, fixed orifice, priority flow control valve designed to manage hydraulic flow efficiently. This valve takes an input flow at port 1 and prioritizes flow to port 3, with any excess being redirected through port 2 for secondary circuit use. The unit requires a specified factory-set flow rating within 10% of the desired setting, offering a maximum pressure of 3000 psi at port 3. Both priority and bypass flows can handle the system's operating pressure, ensuring consistent priority flow regardless of input variations. Bypass flow only activates after satisfying priority needs, with pressure at port 2 potentially exceeding that at port 3. Featuring a sharp-edged orifice design, this model minimizes viscosity-induced flow variations and allows for tunable adjustments up to 25% from the nominal preset using a simple adjust screw mechanism. The Sun floating style construction reduces the risk of internal binding due to installation torque or machining inconsistencies. It fits into a T2A cavity and boasts a capacity of 12 gpm (45 L/min) with a maximum operating pressure of 5000 psi (350 bar) and input flow up to 30 gpm (120 L/min). The valve's hex size is 1-1/8 inches (28.6 mm), requiring an installation torque between 45-50 lbf ft (61-68 Nm). For adjustments, it utilizes an internal hex size screw of 5/32 inches (4 mm) and includes a locknut with a hex size of 9/16 inches (15 mm), torqued between 80-90 lbf in (9-10 Nm). Weighing just .40 lb (.20 kg), it comes equipped with Viton seal kits for optimal performance.
The Sun Hydraulics FRDALBN (Material Number: FRDALBN) is a bypass restrictive, fixed orifice, priority flow control valve designed to manage hydraulic flow efficiently. This valve takes an input flow at port 1 and prioritizes flow to port 3, with any excess being redirected through port 2 for secondary circuit use. The unit requires a specified factory-set flow rating within 10% of the desired setting, offering a maximum pressure of 3000 psi at port 3. Both priority and bypass flows can handle the system's operating pressure, ensuring consistent priority flow regardless of input variations. Bypass flow only activates after satisfying priority needs, with pressure at port 2 potentially exceeding that at port 3. Featuring a sharp-edged orifice design, this model minimizes viscosity-induced flow variations and allows for tunable adjustments up to 25% from the nominal preset using a simple adjust screw mechanism. The Sun floating style construction reduces the risk of internal binding due to installation torque or machining inconsistencies. It fits into a T2A cavity and boasts a capacity of 12 gpm (45 L/min) with a maximum operating pressure of 5000 psi (350 bar) and input flow up to 30 gpm (120 L/min). The valve's hex size is 1-1/8 inches (28.6 mm), requiring an installation torque between 45-50 lbf ft (61-68 Nm). For adjustments, it utilizes an internal hex size screw of 5/32 inches (4 mm) and includes a locknut with a hex size of 9/16 inches (15 mm), torqued between 80-90 lbf in (9-10 Nm). Weighing just .40 lb (.20 kg), it comes equipped with Viton seal kits for optimal performance.
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow may be used in a secondary circuit.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Both priority and bypass flow are usable up to the system operating pressure.
- Priority remains relatively constant regardless of variation in input flow.
- Bypass flow is not available until priority flow requirements are satisfied.
- Pressure at the bypass port (port 2) may exceed pressure at the priority port (port 3).
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- A tuneable adjustment control option provides up to +/- 25% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw. Screw in (CW) to increase flow.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 12 gpm45 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Input Flow | 30 gpm120 L/min. |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ