***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FRDAOAV (Material Number: FRDAOAV) is a bypass-restrictive, fixed-orifice priority flow control valve designed to manage hydraulic flow efficiently. This valve takes an input flow at port 1 and directs it to satisfy the priority flow at port 3. If the input exceeds the required priority flow, the excess is diverted through port 2 for potential use in a secondary circuit. Customers must specify a desired flow rating, which is factory-set within 10% of the requested setting. The valve maintains consistent priority flow even with varying input flows, while bypass flow only becomes available once priority needs are met. It features a sharp-edged orifice design that minimizes variations due to viscosity changes and offers an adjustable control option for up to 25% variation from the nominal preset flow. The adjustment is achieved with three turns of an internal hex screw. The FRDAOAV model incorporates Sun's floating style construction, reducing the risk of internal binding due to excessive installation torque or machining variations. It fits into a T-2A cavity and belongs to Series 2, with a capacity of 12 gpm (45 L/min) and can handle a maximum operating pressure of 5000 psi (350 bar). The valve accommodates maximum input flows up to 30 gpm (120 L/min). Installation requires specific torques: valve installation torque ranges from 45-50 lbf-ft (61-68 Nm), while locknut torque ranges from 80-90 lbf-in (9-10 Nm). The unit weighs approximately .40 lb (0.20 kg) and uses Viton seal kits for cartridge sealing. This product is ideal for applications requiring precise hydraulic control while managing excess fluid efficiently within hydraulic systems.
The Sun Hydraulics FRDAOAV (Material Number: FRDAOAV) is a bypass-restrictive, fixed-orifice priority flow control valve designed to manage hydraulic flow efficiently. This valve takes an input flow at port 1 and directs it to satisfy the priority flow at port 3. If the input exceeds the required priority flow, the excess is diverted through port 2 for potential use in a secondary circuit. Customers must specify a desired flow rating, which is factory-set within 10% of the requested setting. The valve maintains consistent priority flow even with varying input flows, while bypass flow only becomes available once priority needs are met. It features a sharp-edged orifice design that minimizes variations due to viscosity changes and offers an adjustable control option for up to 25% variation from the nominal preset flow. The adjustment is achieved with three turns of an internal hex screw. The FRDAOAV model incorporates Sun's floating style construction, reducing the risk of internal binding due to excessive installation torque or machining variations. It fits into a T-2A cavity and belongs to Series 2, with a capacity of 12 gpm (45 L/min) and can handle a maximum operating pressure of 5000 psi (350 bar). The valve accommodates maximum input flows up to 30 gpm (120 L/min). Installation requires specific torques: valve installation torque ranges from 45-50 lbf-ft (61-68 Nm), while locknut torque ranges from 80-90 lbf-in (9-10 Nm). The unit weighs approximately .40 lb (0.20 kg) and uses Viton seal kits for cartridge sealing. This product is ideal for applications requiring precise hydraulic control while managing excess fluid efficiently within hydraulic systems.
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow may be used in a secondary circuit.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Both priority and bypass flow are usable up to the system operating pressure.
- Priority remains relatively constant regardless of variation in input flow.
- Bypass flow is not available until priority flow requirements are satisfied.
- Pressure at the bypass port (port 2) may exceed pressure at the priority port (port 3).
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- A tuneable adjustment control option provides up to +/- 25% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw. Screw in (CW) to increase flow.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 12 gpm45 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Input Flow | 30 gpm120 L/min. |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |